Product Description

The IC200MDL740 is a 16-point positive logic discrete output module from GE Fanuc’s VersaMax series, designed for DC load switching in industrial control applications. Each output provides precise control with sourcing logic, supporting nominal voltages of 12/24 VDC and a wide operational range. The module includes robust response times and is engineered for seamless integration with VersaMax PLC systems.

Technical Specifications

  • Manufacturer: GE Fanuc

  • Model / Part Number: IC200MDL740

  • Module Type: Positive Logic Output Module

  • Series: VersaMax

  • Number of Outputs: 16 (single group)

  • Logic Type: Positive Logic (Sourcing)

  • Nominal Output Voltage: 12/24 VDC

  • Operational Voltage Range: 10.2–30 VDC

  • Load Current per Point: 0.5 A maximum

  • Maximum Inrush Current: 2.0 A for 100 ms

  • Channel-to-Channel Isolation: None

  • Input/Output Response Time (On/Off): 0.5 ms / 0.5 ms

  • Backplane Current Consumption (5V): 50 mA maximum

  • External Power Supply Requirement: 10.2–30 VDC nominal

  • Points per Common: 16 per group

  • Protection: No internal fuses (each output protected externally)

  • Module Dimensions (D x W x H): 5 cm x 11 cm x 6.68 cm

  • Weight: 0.45 kg

  • Shipping Weight: 1.5 kg

  • Lifecycle Status: Active

Features

  • 16-point positive logic outputs for reliable DC load control

  • Fast response times of 0.5 ms for both ON and OFF switching

  • Compact design for easy panel installation

  • External power supply supports higher load currents

  • Integrated diagnostics for monitoring each output point

Applications

  • Driving DC actuators, solenoids, and relay loads

  • Expanding output capability for VersaMax PLC systems

  • Industrial control systems requiring sourcing-type output modules

FAQ / Comparison

  • Q: How does IC200MDL740 differ from IC200MDL730?
    A: IC200MDL740 provides 16 points compared to 8 points on IC200MDL730 and supports a higher number of controlled devices per group.

  • Q: Is an external power source mandatory?
    A: Yes, to safely supply the output load and maintain proper operation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more