PRODUCT SKU : T8800 1092330000

PRODUCT TYPE : Digital Input Field Termination Assemblies

PRODUCT VENDOR : ICS Triplex


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ICS Triplex T8800, also cataloged as the T8800 (1092330000) Digital Input Field Termination Assembly, operates as a dedicated hardware component for 40-channel field signal conditioning within ICS Triplex Trusted TMR platforms. Serving as the primary physical interface between 2-wire digital field devices and the Trusted TMR 24 Vdc Digital Input Module T8403, this unit processes discrete 24 VDC voltage states across an operating temperature range of -20 to 60 deg C (-4 to 140 deg F).

Hardware Specifications

Parameter Specification
Model T8800 (1092330000)
Brand ICS Triplex
Origin United Kingdom
Dimensions 100 mm x 50 mm x 30 mm
Operating Temp -20 to 60 deg C (-4 to 140 deg F)
Power Consumption Passive Line Conditioning (Field Bus Dependent)
Input Voltage 24 VDC
Input Channels 40 input channels per FTA
Communication Protocols Modbus, TCP/IP, EtherNet/IP
Memory Capacity 2 GB RAM, 16 GB Flash Memory
Enclosure Material Stainless Steel
Protection Rating IP67
Field Connection Industry-standard 2-wire field device connections
System Compatibility Trusted TMR 24 Vdc Digital Input Module T8403
Certifications CE, RoHS

Triple Modular Redundancy and Fault Isolation

The ICS Triplex T8800 field termination assembly integrates directly into triple modular redundancy (TMR) 2oo3 architecture designs required for SIL3 certification compliance. Galvanic isolation between field loops, chassis ground, and system backplane circuitry suppresses transverse-mode noise and ground potential shifts across all 40 digital input channels. In the event of field wiring fault conditions or sensor signal disruption, the assembly maintains signal routing integrity to ensure uncorrupted state data reaching the T8403 module for fail-safe state execution.

Frequently Asked Questions

Q: How does the T8800 field termination assembly interface with the T8403 Digital Input Module?

A: The T8800 connects 2-wire 24 VDC field sensors directly to dedicated terminal blocks, routing conditioned parallel digital inputs directly into the T8403 TMR input module connector header.

Q: Can the T8800 FTA withstand direct exposure to dust and liquid in harsh industrial environments?

A: Yes, the T8800 features a rugged stainless steel enclosure engineered and certified to an IP67 ingress protection rating.

Field Installation Guidelines

  1. Mount the T8800 assembly onto a standard 35 mm DIN rail inside the enclosure cabinet and ensure the grounding latch locks firmly onto the rail.
  2. Terminate 2-wire field device leads into designated input channel screw terminals, maintaining strict polarity for 24 VDC loops.
  3. Route field wiring separate from high-voltage AC lines to minimize electromagnetic interference, observing a minimum separation distance of 200 mm.
  4. Secure multi-core interface cabling between the T8800 FTA board and the T8403 TMR Digital Input Module, ensuring cable retention latches are fully engaged.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more
Hot Standby vs. Cold Standby Redundancy in Industrial Automation

Hot Standby vs. Cold Standby Redundancy in Industrial Automation

System availability determines process safety and productivity in industrial automation. Control engineers deploy redundancy to eliminate single points of failure. This technical guide evaluates Hot Standby vs. Cold Standby architectures, comparing failover speeds, memory sync, cost trade-offs, and field selection criteria.

Read more
ON-OFF Controller vs. PID Controller: Industrial Control System Evaluation

ON-OFF Controller vs. PID Controller: Industrial Control System Evaluation

Selecting the right control strategy impacts process stability, efficiency, and equipment lifespan. This technical comparison evaluates binary ON-OFF and continuous PID control algorithms, analyzing their mathematical behavior, operational differences, and practical selection criteria for factory automation.
Read more