Skip to content

What are you looking for?


You may also like

SB401-50 S1 | Yokogawa | CENTUM CS 3000 ESB Bus Interface ModuleSB401-50 S1 | Yokogawa | CENTUM CS 3000 ESB Bus Interface ModuleSB401-50 S1 | Yokogawa | CENTUM CS 3000 ESB Bus Interface Module
SB401-50 S1 | Yokogawa | CENTUM CS 3000 ESB Bus Interface Module
SB401-50 S1 | Yokogawa | CENTUM CS 3000 ESB Bus Interface Module
SB401-50 S1 | Yokogawa | CENTUM CS 3000 ESB Bus Interface Module

SB401-50 S1 | Yokogawa | CENTUM CS 3000 ESB Bus Interface Module


Only 10 left - Selling fast

PRODUCT SKU : SB401-50 S1

PRODUCT TYPE : Bus Interface Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa SB401-50 S1 functions as a high-speed ESB Bus Interface Module within the CENTUM CS 3000 Distributed Control System (DCS) architecture. This module facilitates the communication link between the Field Control Unit (FCU) and remote I/O nodes via the Extended Serial Backplane (ESB). By managing deterministic data packets, the SB401-50 S1 ensures that real-time process data from field instrumentation reaches the central processor with minimal latency.

Part Number Breakdown

The SB401 series utilizes specific codes to define its functional style and protection rating:

Code Type Description
SB401 Model ESB Bus Interface Module
-5 Standard Standard type with no explosion protection
0 Basic Basic functional type for standard I/O nodes
S1 Style Style S1 hardware revision for optimized signal integrity

Technical Specifications

The SB401-50 S1 adheres to the following high-performance standards for industrial data transport:

  • Manufacturer: Yokogawa

  • Module Type: ESB Bus Interface (Slave)

  • System Compatibility: CENTUM CS 3000, CS 1000

  • Transmission Speed: 128 Mbps

  • Bus Interface: Dual-connector support for redundant path communication

  • Configuration: Standard Basic Type

  • Condition: 100% Brand New and Original

Engineering Advantages

  • Deterministic Throughput: The SB401-50 S1 utilizes a fixed 128 Mbps bandwidth to eliminate the data collisions common in standard Ethernet architectures. This ensures that the control system executes safety interlocks and process loops within fixed, predictable scan times.

  • Redundant Path Switching: This module supports dual ESB bus cabling. In the event of a cable break or master-side failure, the SB401-50 S1 switches to the secondary communication path instantaneously, preventing system trips and maintaining process visibility.

  • Signal Conditioning via Style S1: The S1 hardware revision incorporates updated electronic components that enhance signal filtering. This design minimizes the impact of electromagnetic interference (EMI) within the marshalling cabinet, protecting the integrity of process data in noisy industrial environments.

  • Simplified Hardware Layout: The "Basic Type" architecture provides a plug-and-play interface for standard I/O nodes. This simplifies the expansion of the DCS, allowing engineers to add remote racks without requiring complex gateway configurations or software re-mapping.

FAQs

  • Is this Yokogawa SB401-50 S1 unit provided as new or used?

    We supply this module exclusively as 100% Brand New and Original equipment. Every unit arrives in its original factory-sealed Yokogawa packaging, ensuring zero previous runtime and maximum reliability.

  • Can I use the SB401-50 in hazardous areas?

    No. The "-5" suffix indicates the Standard Type with no explosion protection. You must install this module in a non-hazardous area or within a suitably rated, purged enclosure according to your plant's safety guidelines.

  • Does the SB401-50 S1 support both CENTUM CS 3000 and CENTUM VP?

    The SB401-50 S1 primarily serves the CENTUM CS 3000 and CS 1000 systems. While some backward compatibility exists, we generally recommend the SSB401 series for modern CENTUM VP architectures. Please verify your specific controller firmware before installation.

  • How do I verify the communication status of this module?

    The module front panel features diagnostic LEDs. A steady green "ACT" light indicates the module is actively communicating on the ESB bus. If the "ERR" light activates, consult the system's HIS (Human Interface Station) for detailed error codes regarding bus synchronization or hardware failure.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more