Skip to content

What are you looking for?


You may also like

S9260DE-01 | Yokogawa N-ESB Bus 16-Input / 32-Output Digital I/O ModuleS9260DE-01 | Yokogawa N-ESB Bus 16-Input / 32-Output Digital I/O ModuleS9260DE-01 | Yokogawa N-ESB Bus 16-Input / 32-Output Digital I/O Module
S9260DE-01 | Yokogawa N-ESB Bus 16-Input / 32-Output Digital I/O Module
S9260DE-01 | Yokogawa N-ESB Bus 16-Input / 32-Output Digital I/O Module
S9260DE-01 | Yokogawa N-ESB Bus 16-Input / 32-Output Digital I/O Module

S9260DE-01 | Yokogawa N-ESB Bus 16-Input / 32-Output Digital I/O Module


Only 10 left - Selling fast

PRODUCT SKU : S9260DE-01

PRODUCT TYPE : Digital I/O Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The S9260DE-01 is a high-density digital interface module engineered for the Yokogawa N-ESB (Next Generation Enclosed System Bus) environment. This unit provides a hybrid solution for industrial control, integrating 16 discrete input channels and 32 discrete output channels within a single compact footprint. Designed for high-integrity signaling, the S9260DE-01 serves as a vital bridge between field sensors, actuators, and the central processing unit, offering deterministic response times required for complex automation logic.

Built to withstand the electrical rigors of plant environments, the module features advanced galvanic isolation, rated at 1500V AC. This protective barrier prevents ground loops and transient surges from propagating from the field wiring to the sensitive backplane electronics, ensuring long-term system stability and hardware longevity.

Detailed Technical Specifications

  • Input Capacity: 16 points, discrete digital sensing

  • Output Capacity: 32 points, discrete digital control

  • Signal Voltage: 24V DC nominal (0V to 24V DC range) for both I/O sections

  • Bus Architecture: N-ESB Bus (Next-generation high-speed serial bus)

  • Dielectric Strength: 1500V AC for 60 seconds (Power-to-Ground)

  • Thermal Performance: Rated for continuous operation from -20°C to +60°C

  • Mechanical Design: Modular hot-swap compatible housing for minimal downtime

  • Mounting: Optimized for high-density cabinet rail installation

System Integration & Applications

The S9260DE-01 is typically deployed in large-scale Distributed Control Systems (DCS) where I/O density is a priority. Its 1:2 input-to-output ratio makes it particularly effective for motor control centers (MCC), where fewer start/stop confirmations (inputs) are paired with multiple status lamps and interlock solenoids (outputs). It is widely used in the chemical, pharmaceutical, and energy sectors for reliable sequence-of-events recording and actuation.

Technical FAQ

How does the N-ESB interface differ from standard ESB?The N-ESB interface utilized by the S9260DE-01 offers enhanced bandwidth and improved noise immunity compared to older bus generations, allowing for more stable data transmission over longer distances within the control cabinet.

Does this module require external field power?Yes, while the logic side is powered via the backplane, the 24V DC digital signals for field devices typically require a secondary external power supply to drive the loads and sense the input contacts.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more