PRODUCT SKU : IC695ALG112

PRODUCT TYPE : Isolated Analog Input Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The IC695ALG112-EA from GE Fanuc is a 12-channel isolated analog input module designed for the PACSystems RX3i platform. Each input channel is individually isolated and configurable for current or voltage signals, providing high precision and robust signal integrity for demanding industrial control and monitoring applications.

This module supports a wide range of signal types and includes built-in filtering and overvoltage protection, ensuring reliable operation under harsh electrical environments.

Technical Specifications

  • Model: IC695ALG112-EA

  • Manufacturer: GE Fanuc Emerson

  • Product Type: Isolated Analog Voltage/Current Input Module

  • Series: PACSystems RX3i

  • Number of Channels: 12 isolated analog input channels

  • Signal Types Supported:

    • Current: 0–20 mA, 4–20 mA, ±20 mA

    • Voltage: ±10 V, 0–10 V, +5 V, 0–5 V, 1–5 V

  • Resolution: 16-bit analog-to-digital conversion

  • Input Impedance:

    • 500 kΩ for voltage input

    • 250 Ω ±1% for current input

  • Filter Options: Up to 6000 Hz configurable per channel

  • Update Rate: 1 ms per channel

  • Accuracy: ±0.19% at 25°C; ±0.2% across full temperature range

  • Protection:

    • Overvoltage: ±35 VDC continuous

    • Overcurrent: ±35 mA continuous

  • Power Requirements:

    • 490 mA @ 5 VDC

    • 310 mA @ 3.3 VDC

    • 500 mA @ 24 VDC (external isolated supply)

  • Power Dissipation: Maximum 4.89 W

  • Isolation Voltage: 250 VAC continuous / 1500 VAC for 1 minute

  • Operating Temperature: 0°C to +60°C

  • Mounting: RX3i Universal Backplane

Applications

  • Industrial automation systems requiring precise analog signal measurement

  • Process control and instrumentation monitoring

  • Integration with PACSystems RX3i CPUs for analog data acquisition

  • Systems needing channel-to-channel isolation to prevent signal interference

FAQ

  • Q: How many analog channels does the IC695ALG112-EA provide?
    A: It offers 12 isolated input channels, each configurable for voltage or current signals.

  • Q: Does this module include overvoltage protection?
    A: Yes, up to ±35 VDC continuous protection per channel.

  • Q: What is the data resolution?
    A: 16-bit ADC for high-precision signal conversion.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more