Skip to content

What are you looking for?


You may also like

IC695PBS301 | GE Fanuc RX3i PROFIBUS Interface ModuleIC695PBS301 | GE Fanuc RX3i PROFIBUS Interface ModuleIC695PBS301 | GE Fanuc RX3i PROFIBUS Interface Module
IC695PBS301 | GE Fanuc RX3i PROFIBUS Interface Module
IC695PBS301 | GE Fanuc RX3i PROFIBUS Interface Module
IC695PBS301 | GE Fanuc RX3i PROFIBUS Interface Module

IC695PBS301 | GE Fanuc RX3i PROFIBUS Interface Module


Only 10 left - Selling fast

PRODUCT SKU : IC695PBS301

PRODUCT TYPE : Communication Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The IC695PBS301 is a PROFIBUS DP Slave Communication Module developed by GE Fanuc (Emerson) for the PACSystems RX3i platform. This module allows RX3i controllers to operate as slave devices on a PROFIBUS network, providing seamless interoperability with third-party PROFIBUS DP masters. Engineered for distributed control systems, it delivers fast, deterministic data exchange and reliable communication in complex automation environments.

Technical Specifications

  • Model Number: IC695PBS301

  • Manufacturer: GE Fanuc Emerson

  • Product Type: PROFIBUS DP Slave Communication Module

  • Supported Protocols: PROFIBUS DP-V0 and DP-V1

  • Data Capacity: Up to 244 bytes input and 244 bytes output

  • Baud Rate: 9.6 Kbps to 12 Mbps (automatic detection)

  • Connector Type: 9-pin D-sub female (standard PROFIBUS interface)

  • Power Consumption: 440 mA @ 3.3 VDC

  • Backplane Compatibility: RX3i Universal Backplane

  • Slot Requirement: Single-slot module

  • Operating Temperature: 0°C to +60°C

  • Storage Temperature: -40°C to +85°C

  • LED Indicators: PROFIBUS OK, Network, Module Status

  • Firmware Updates: Supported via host CPU using WinLoader utility

Key Features

  • Full PROFIBUS DP Slave Functionality: Supports cyclic data exchange and DP-V1 messaging for efficient communication.

  • High-Speed Performance: Designed for deterministic real-time data handling with minimal latency.

  • Automatic Baud Rate Detection: Simplifies setup and integration with existing PROFIBUS networks.

  • Diagnostic LED Indicators: Provide immediate status feedback for power, communication, and module health.

  • Hot-Swappable Design: Enables module replacement without system shutdown when supported.

  • Seamless RX3i Integration: Configured through Machine Edition Logic Developer–PLC software.

  • Industrial-Grade Construction: Built for reliable performance in high-vibration and high-temperature environments.

Applications

  • Distributed control systems (DCS)

  • Industrial automation and process control

  • Machine-to-machine communication

  • PROFIBUS-based networked I/O systems

FAQ

  • Q: What PROFIBUS versions does the IC695PBS301 support?
    A: It supports both DP-V0 and DP-V1 protocols for cyclic and acyclic data communication.

  • Q: Can this module auto-detect network speed?
    A: Yes, it automatically detects baud rates from 9.6 Kbps to 12 Mbps.

  • Q: Is the IC695PBS301 hot-swappable?
    A: Yes, it can be replaced while the system remains operational under supported conditions.

  • Q: What is the maximum data exchange capacity?
    A: It supports 244 bytes of input and 244 bytes of output data.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more