PRODUCT SKU : IC695PBS301

PRODUCT TYPE : Communication Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The IC695PBS301 is a PROFIBUS DP Slave Communication Module developed by GE Fanuc (Emerson) for the PACSystems RX3i platform. This module allows RX3i controllers to operate as slave devices on a PROFIBUS network, providing seamless interoperability with third-party PROFIBUS DP masters. Engineered for distributed control systems, it delivers fast, deterministic data exchange and reliable communication in complex automation environments.

Technical Specifications

  • Model Number: IC695PBS301

  • Manufacturer: GE Fanuc Emerson

  • Product Type: PROFIBUS DP Slave Communication Module

  • Supported Protocols: PROFIBUS DP-V0 and DP-V1

  • Data Capacity: Up to 244 bytes input and 244 bytes output

  • Baud Rate: 9.6 Kbps to 12 Mbps (automatic detection)

  • Connector Type: 9-pin D-sub female (standard PROFIBUS interface)

  • Power Consumption: 440 mA @ 3.3 VDC

  • Backplane Compatibility: RX3i Universal Backplane

  • Slot Requirement: Single-slot module

  • Operating Temperature: 0°C to +60°C

  • Storage Temperature: -40°C to +85°C

  • LED Indicators: PROFIBUS OK, Network, Module Status

  • Firmware Updates: Supported via host CPU using WinLoader utility

Key Features

  • Full PROFIBUS DP Slave Functionality: Supports cyclic data exchange and DP-V1 messaging for efficient communication.

  • High-Speed Performance: Designed for deterministic real-time data handling with minimal latency.

  • Automatic Baud Rate Detection: Simplifies setup and integration with existing PROFIBUS networks.

  • Diagnostic LED Indicators: Provide immediate status feedback for power, communication, and module health.

  • Hot-Swappable Design: Enables module replacement without system shutdown when supported.

  • Seamless RX3i Integration: Configured through Machine Edition Logic Developer–PLC software.

  • Industrial-Grade Construction: Built for reliable performance in high-vibration and high-temperature environments.

Applications

  • Distributed control systems (DCS)

  • Industrial automation and process control

  • Machine-to-machine communication

  • PROFIBUS-based networked I/O systems

FAQ

  • Q: What PROFIBUS versions does the IC695PBS301 support?
    A: It supports both DP-V0 and DP-V1 protocols for cyclic and acyclic data communication.

  • Q: Can this module auto-detect network speed?
    A: Yes, it automatically detects baud rates from 9.6 Kbps to 12 Mbps.

  • Q: Is the IC695PBS301 hot-swappable?
    A: Yes, it can be replaced while the system remains operational under supported conditions.

  • Q: What is the maximum data exchange capacity?
    A: It supports 244 bytes of input and 244 bytes of output data.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more