The Foxboro P0926JMA, also cataloged as the P0926JMA Modular Baseplate, operates as a dedicated hardware component for structural mounting and backplane signal bus interconnection within Foxboro I/A Series DCS environments. It provides direct physical execution of modular 8-slot Field Bus Module (FBM) carrier housing and redundant power rail distribution. The assembly routes internal communication buses while regulating backplane voltage profiles to mounted I/O modules.

Hardware Specifications

Parameter Specification
Model P0926JMA
Brand Foxboro
Origin USA
Weight 0.2 kg (0.44 lbs)
Dimensions 102.2 cm x 12.4 cm x 12.6 cm
Operating Temp 0 to +60 deg C
Power Consumption Passive (Backplane distribution: +5 VDC)
Slot Capacity 8 Slots (Modular FBM)
Mounting Type DIN Rail Mount
Storage Temp -40 to +85 deg C
Humidity Rating 5-95% RH (non-condensing)

DCS Backplane Communication and Channel Isolation

The Foxboro P0926JMA baseplate integrates high-density multi-layer printed circuit traces engineered to maintain deterministic bus communications across all 8 module positions. Designed for Foxboro I/A Series architectures, the backplane traces deliver channel-to-channel isolation between power distribution buses and differential fieldbus communication loops. It conditions +5 VDC backplane power to preserve signal integrity and support transparent pass-through for 4-20 mA HART loop protocol field telemetry without inductive coupling.

Frequently Asked Questions

Q: Does the P0926JMA baseplate support hot-swapping of individual Field Bus Modules (FBMs)?

A: Yes, the backplane bus logic and connector pins allow live insertion and removal of individual FBM units without interrupting power or signal communication on adjacent operating slots.

Q: How is backplane power redundancy managed across the 8 slots of the P0926JMA?

A: The baseplate features integrated dual power distribution rails that route primary and secondary +5 VDC supply buses across all slots, ensuring continuous operation if one power feed degrades.

Field Installation Guidelines

  1. Mount the P0926JMA baseplate horizontally onto standard DIN rails, ensuring all retention clamps latch tightly against the rail base.
  2. Verify that adjacent baseplates connect via dedicated HDLC interface cables before applying system backplane power.
  3. Connect the primary system ground strap to the dedicated grounding stud on the baseplate frame to ensure full EMI/RFI shielding protection.
  4. Align module keyways before inserting FBM units into any of the 8 slots to prevent pin bending on the +5 VDC backplane connector headers.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more
Hot Standby vs. Cold Standby Redundancy in Industrial Automation

Hot Standby vs. Cold Standby Redundancy in Industrial Automation

System availability determines process safety and productivity in industrial automation. Control engineers deploy redundancy to eliminate single points of failure. This technical guide evaluates Hot Standby vs. Cold Standby architectures, comparing failover speeds, memory sync, cost trade-offs, and field selection criteria.

Read more
ON-OFF Controller vs. PID Controller: Industrial Control System Evaluation

ON-OFF Controller vs. PID Controller: Industrial Control System Evaluation

Selecting the right control strategy impacts process stability, efficiency, and equipment lifespan. This technical comparison evaluates binary ON-OFF and continuous PID control algorithms, analyzing their mathematical behavior, operational differences, and practical selection criteria for factory automation.
Read more