The Foxboro Invensys P0926HT, also cataloged as the P0926HT Horizontal Modular Baseplate, operates as a dedicated hardware component for multi-slot module mounting and backplane bus signal distribution within Foxboro I/O architecture platforms. Configured to support up to 8 active hardware modules, the unit executes direct physical backplane interconnections across power rails and communication buses without active microprocessor mediation.

Hardware Specifications

Parameter Specification
Model P0926HT
Brand Foxboro / Invensys
Origin Standard Manufacturing Facility
Weight 0.5 lb (0.23 kg)
Dimensions 4.8 x 2.8 x 1.2 in (122 x 71 x 30 mm)
Operating Temp Standard Industrial Range (-20 deg C to 60 deg C)
Power Consumption Passive Backplate Component (0 W)
Slot Capacity 8 Slots
Insulation Voltage 500 VDC
Input Range Supports -20 to 60 VDC, 4 to 20 mA, 0 to 10 VDC, 0 to 200 mV

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

Within process control installations, this baseplate routes active signals from field terminals to installed I/O cards supporting 4-20 mA HART loop protocol instruments and voltage-based transducers. Internal backplane traces maintain strict channel-to-channel isolation and an insulation voltage rating of 500 VDC, preventing ground loops, suppressing electromagnetic interference, and protecting downstream system buses from transient electrical surges originating in field wiring.

Frequently Asked Questions

Q: Does the P0926HT baseplate support hot-swapping of installed I/O modules?

A: Yes, the mechanical slot design allows live insertion and removal of compatible FBM modules on active baseplates, provided power distribution to the specific slot is managed according to system safety procedures.

Q: How does the baseplate manage common-mode noise across multi-channel inputs?

A: The backplate layout incorporates integrated grounding planes and high common-mode rejection filtering paths to maintain signal fidelity across all 8 modular slots.

Field Installation Guidelines

  • Mount the baseplate horizontally onto an approved DIN rail or structural backplane panel inside an industrial enclosure using secure mechanical fasteners.
  • Ensure all chassis grounding studs are connected directly to the cabinet ground busbar using low-impedance copper conductors to preserve electromagnetic shielding.
  • Verify that module slot alignment pins are undamaged and fully engaged prior to inserting any I/O card into the 8-slot array.
  • Maintain clear airflow paths around the modular assembly to prevent localized thermal accumulation within the cabinet.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more
How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

Establishing a reliable hardware link between a programming terminal and a Siemens SIMATIC controller is essential for engineering workflows. Field engineers rely on distinct physical layers, ranging from legacy serial connections to high-speed Industrial Ethernet protocols. Modern factory automation environments prioritize fast data transfer and seamless driver integration. Selecting the correct connection method simplifies program downloads, online monitoring, and system troubleshooting in complex control systems.

Read more