Product Description

The MVI56E-MNET module from ProSoft Technology is an enhanced Modbus TCP/IP client/server communication interface designed for Allen Bradley ControlLogix systems. It provides high-speed Ethernet connectivity, expanded data handling, and diagnostic features for reliable integration of Modbus devices into ControlLogix platforms.

Key Specifications

  • Manufacturer: Allen Bradley / ProSoft Technology

  • Model: MVI56E-MNET

  • Part Number: MVI56E-MNET

  • Product Type: Modbus TCP/IP Enhanced Client/Server Module

  • Product Line: ControlLogix

  • Weight: 3.00 lbs (1.36 kg)

  • Backplane Current Load: 800 mA @ 5 VDC, 3 mA @ 24 VDC

  • Module Width: Single slot

  • Compatible Rack: ControlLogix chassis (local or remote)

  • Data Size: 5000 words, 16-bit registers

  • User-Definable Memory Mapping: Up to 5000 registers

  • Configuration Tools: Add-On-Instruction (AOI), sample ladder logic

  • Compatible Processors: ControlLogix processor version 10 or higher

  • Communication Port: 1 × RJ45 Ethernet interface

  • Ethernet Speed: 10/100 Mbps (Base-T)

  • LED Indicators: Battery status (ERR), application status (APP), module status (OK)

  • Operating Temperature: 0–60°C (32–140°F)

  • Storage Temperature: –40–85°C (–40–185°F)

  • Shock Resistance: 30 g operational

  • Relative Humidity: 5–95% non-condensing

  • Protection: Conformal-coated for harsh environments

Core Features

  • Enhanced Modbus TCP/IP client/server communication for ControlLogix systems

  • Large data handling capacity with flexible memory mapping

  • AOI and ladder logic integration for simplified configuration

  • Diagnostic LEDs for real-time monitoring of module and communication status

  • Rugged design with conformal coating for industrial reliability

Application Scenarios

  • Integration of Modbus TCP/IP devices into ControlLogix systems

  • SCADA and distributed control systems requiring Modbus communication

  • Industrial automation setups needing floating-point data handling and Ethernet connectivity

FAQ

  • Q: How many registers can be mapped?  A: Up to 5000 registers.

  • Q: What configuration tools are supported?  A: Add-On-Instruction (AOI) and sample ladder logic.

  • Q: What processors are compatible?  A: ControlLogix processors version 10 or higher.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more