Skip to content

What are you looking for?


You may also like

MC-TDID72 51303928-150 | Honeywell 72-Channel Digital Input FTA ModuleMC-TDID72 51303928-150 | Honeywell 72-Channel Digital Input FTA ModuleMC-TDID72 51303928-150 | Honeywell 72-Channel Digital Input FTA Module
MC-TDID72 51303928-150 | Honeywell 72-Channel Digital Input FTA Module
MC-TDID72 51303928-150 | Honeywell 72-Channel Digital Input FTA Module
MC-TDID72 51303928-150 | Honeywell 72-Channel Digital Input FTA Module

MC-TDID72 51303928-150 | Honeywell 72-Channel Digital Input FTA Module


Only 10 left - Selling fast

PRODUCT SKU : MC-TDID72 51303928-150

PRODUCT TYPE : Digital Input FTA

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The MC-TDID72 (51303928-150) is a high-density Digital Input Field Termination Assembly (FTA) engineered for large-scale Honeywell Experion PKS and legacy TDC 3000 control systems. This professional-grade interface facilitates the centralized acquisition of up to 72 independent discrete signals, acting as the critical link between field-side hardware and the system’s Input/Output Processors (IOP). Designed for industrial-scale monitoring, the MC-TDID72 is optimized for high-availability environments, featuring a conformal-coated PCB that provides superior resistance to moisture, dust, and corrosive atmospheric contaminants commonly found in refineries and chemical processing plants.

Technical Specifications

  • Model Identification: MC-TDID72

  • Part Number: 51303928-150

  • Functional Category: Digital Input Field Termination Assembly (FTA)

  • Channel Density: 72 Independent Discrete Input Channels

  • Input Voltage Compatibility: 24 VDC Nominal (Supports dry contact and powered inputs)

  • Signal Processing: Discrete ON/OFF State Acquisition

  • System Interface: Compatible with Honeywell MU/MC series Digital Input IOPs

  • Redundancy Support: Dual-cable ports for redundant processor configurations

  • Diagnostic Interface: Integrated LED status indicators per channel

  • Wiring Method: High-retention compression-style screw terminals

  • Environmental Protection: Full Conformal Coating (MC Designation)

  • Operating Temperature: -40°C to +70°C

  • Physical Form Factor: Standard Honeywell Size B FTA (~307 mm)

High-Density Monitoring and Diagnostics

The MC-TDID72 (51303928-150) is a versatile solution for facilities requiring extensive monitoring of limit switches, pushbuttons, motor starter contacts, and alarm signals. Its 72-channel architecture significantly reduces the physical footprint within the I/O cabinet compared to lower-density modules. For maintenance personnel, the integrated LED array provides instantaneous visual verification of field states, streamlining the commissioning and troubleshooting of complex control loops. Furthermore, the module's 24VDC logic is designed with robust isolation to maintain signal integrity in high-EMI environments.

Frequently Asked Questions

  • Can this FTA be used with 120VAC field signals?

    No. The MC-TDID72 (51303928-150) is specifically designed for 24VDC logic. Interfacing 120VAC signals directly will cause immediate hardware failure. An interposing relay or an AC-specific FTA must be used for higher voltage signals.

  • Does the "MC" prefix signify a specific hardware version?

    Yes. In the Honeywell ecosystem, the "MC" prefix indicates that the board is conformal coated for harsh environments, whereas the "MU" prefix generally denotes a standard, non-coated version of the same functional board.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more