Skip to content

What are you looking for?


You may also like

IS200ERGTH1AAA | GE EX2100 Ground Detector Terminal Interface BoardIS200ERGTH1AAA | GE EX2100 Ground Detector Terminal Interface BoardIS200ERGTH1AAA | GE EX2100 Ground Detector Terminal Interface Board
IS200ERGTH1AAA | GE EX2100 Ground Detector Terminal Interface Board
IS200ERGTH1AAA | GE EX2100 Ground Detector Terminal Interface Board
IS200ERGTH1AAA | GE EX2100 Ground Detector Terminal Interface Board

IS200ERGTH1AAA | GE EX2100 Ground Detector Terminal Interface Board


Only 10 left - Selling fast

PRODUCT SKU : IS200ERGTH1AAA

PRODUCT TYPE : Ground Detector Terminal Board

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The IS200ERGTH1AAA is a General Electric terminal board designed for the EX2100 excitation control system. Known as the Exciter Regulator Ground Detector Terminal Board, it provides monitoring and signal interfacing functions for excitation systems. Equipped with a 32‑bit digital signal processor, the board ensures accurate detection and reliable performance in turbine control applications.

Technical Specifications

  • Manufacturer: General Electric (GE)

  • Series: EX2100 Excitation Control System

  • Product Type: Exciter Ground Detector Terminal Board

  • Model Number: IS200ERGTH1AAA

  • Analog Output Current: 0–20 mA

  • Excitation Voltage: 24 VDC

  • Maximum Lead Resistance: 15 Ω

  • Processor: 32‑bit digital signal processor

  • Operating Temperature Range: 30 °C to 50 °C

  • Frequency: 50 or 60 Hz

  • Dimensions: 17.8 cm (H) × 33.02 cm (W)

  • Weight: 2 lbs (0.9 kg)

  • Country of Manufacture: USA

  • Manual Reference: GEI‑100531

  • Repair Lead Time: 3–7 days

  • Availability: In stock

Application Scenarios

This board is typically used in:

  • Excitation control systems requiring ground detection and signal monitoring

  • Gas and steam turbine platforms within the EX2100 series

  • Industrial power generation facilities where precise excitation regulation is critical

FAQ

Q: What is the primary function of the IS200ERGTH1AAA?  A: It serves as a ground detector terminal board for excitation systems.

Q: What processor is used in this board?  A: A 32‑bit digital signal processor.

Q: What is the operating temperature range?  A: 30 °C to 50 °C.

Q: What excitation voltage does the board support?  A: 24 VDC.

Q: What system is this board designed for?  A: It is designed for the GE EX2100 excitation control system.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more
Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Modern industrial automation heavily relies on Programmable Logic Controllers (PLCs) to drive factory floor efficiency. Over my 15 years as an industrial automation expert working with DCS, TSI, and control systems, I have seen PLCs evolve into the central nervous system of modern manufacturing. Selecting the right controller requires a deep understanding of PLC types based on physical size, hardware architecture, and power supply configurations.

Read more