Skip to content

What are you looking for?


You may also like

IC660BBA026 GE Fanuc Analog Input Module for PLC SystemsIC660BBA026 GE Fanuc Analog Input Module for PLC SystemsIC660BBA026 GE Fanuc Analog Input Module for PLC Systems
IC660BBA026 GE Fanuc Analog Input Module for PLC Systems
IC660BBA026 GE Fanuc Analog Input Module for PLC Systems
IC660BBA026 GE Fanuc Analog Input Module for PLC Systems

IC660BBA026 GE Fanuc Analog Input Module for PLC Systems


Only 10 left - Selling fast

PRODUCT SKU : IC660BBA026

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview:
The IC660BBA026 from GE Fanuc is a rugged, high-precision analog input module in the Genius I/O series. Designed to support six independent analog inputs, it provides reliable 4–20mA signal acquisition with microamp resolution, ensuring precise monitoring of industrial processes. This module features user-selectable input conversion times, extensive isolation protection, and clear LED status indicators for easy diagnostics.

Key Features:

  • Six 4–20mA analog input channels

  • High-accuracy measurements with ±0.1% full-scale reading

  • Input resolution: 1 µA for precise signal capture

  • User-selectable input conversion times from 16.6ms to 400ms

  • Full channel isolation: 1500V block-to-block, 1500V group-to-group

  • Supports standard Genius Protocol communication

  • LED indicators for Unit OK and I/O Enabled

  • Heat dissipation: 12 W maximum

  • Compact and rugged design suitable for harsh industrial environments

Technical Specifications:

  • Model Number: IC660BBA026

  • Number of Inputs: 6 analog inputs

  • Points per Common: 1 group of 6

  • Output Signals: 4–20 mA

  • Supply Voltage Range: 18–56 VDC

  • Block Power: 115V AC / 125V DC

  • Input Accuracy: ±0.1% full-scale

  • Input Resolution: 1 µA

  • Input Conversion Time: 16.6–400 ms (user configurable)

  • Block-to-Block Isolation: 1500 V RMS

  • Group-to-Group Isolation: 1500 V RMS

  • Heat Dissipation: 12 W

  • Dimensions (HxWxD): 8.83 × 3.34 × 3.91 in

  • Weight: 2 lbs (0.91 kg)

  • LED Indicators: Unit OK, I/O Enabled

Applications:

  • Distributed control systems and Genius I/O networks

  • Machine automation requiring precise analog signal acquisition

  • Process monitoring in industrial environments

  • Integration with GE Fanuc PLC systems for high-reliability data input

FAQ:
Q: Is this module factory-new and original?
A: Yes, all units are original GE Fanuc products.

Q: Can the module handle harsh industrial conditions?
A: Yes, IC660BBA026 is designed for rugged environments with high isolation protection.

Q: How fast can inputs be converted?
A: Conversion times are user-selectable between 16.6 ms and 400 ms per channel.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more