Skip to content

What are you looking for?


You may also like

Honeywell MC-TDOR22 51309150-175 Digital Output Field Termination AssemblyHoneywell MC-TDOR22 51309150-175 Digital Output Field Termination AssemblyHoneywell MC-TDOR22 51309150-175 Digital Output Field Termination Assembly
Honeywell MC-TDOR22 51309150-175 Digital Output Field Termination Assembly
Honeywell MC-TDOR22 51309150-175 Digital Output Field Termination Assembly
Honeywell MC-TDOR22 51309150-175 Digital Output Field Termination Assembly

Honeywell MC-TDOR22 51309150-175 Digital Output Field Termination Assembly


Only 10 left - Selling fast

PRODUCT SKU : MC-TDOR22 51309150-175

PRODUCT TYPE : Digital Output FTA

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Honeywell MC-TDOR22 (Part No. 51309150-175) is a high-performance Digital Output Field Termination Assembly (FTA) designed to interface seamlessly with the Experion Process Knowledge System (PKS) and FSC Distributed Control Systems (DCS). It provides secure relay-based outputs for controlling field devices while ensuring reliable operation under demanding industrial conditions.

Technical Specifications

  • Manufacturer: Honeywell

  • Model Number: MC-TDOR22

  • Part Number: 51309150-175

  • Product Type: Digital Output FTA

  • Number of Output Channels: 16 independent digital outputs

  • Output Type: Relay contact

  • Contact Rating: 240 V AC / 125 V DC

  • Isolation Voltage: 500 V RMS between channels

  • Power Consumption: 0.5 W per channel

  • Input Voltage: 24 VDC nominal

  • Operating Temperature: -40°C to +85°C

  • Storage Temperature: -40°C to +85°C

  • Humidity Tolerance: 5% to 95% RH, non-condensing

  • Mounting: DIN-rail compatible

  • Dimensions: 13.5 cm × 7.1 cm × 2 cm

  • Weight: 1 kg

  • Status Indicators: Channel-level LED for output status

Applications

The MC-TDOR22 is ideal for:

  • Field device actuation and relay control in Honeywell Experion PKS systems

  • Distributed control system outputs in FSC architectures

  • Industrial processes requiring reliable 16-channel digital output control

  • Petrochemical, refining, and power generation environments with extreme temperature tolerance

FAQ

Q1: Can this module handle both AC and DC loads?
A1: Yes, each relay contact is rated for 240 V AC or 125 V DC.

Q2: Is it suitable for outdoor installation?
A2: The MC-TDOR22 is designed for indoor use; proper enclosure or cabinet protection is required for outdoor deployment.

Q3: How is it mounted in a control panel?
A3: The module is DIN-rail compatible, allowing secure and modular installation in standard I/O racks.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more