Skip to content

What are you looking for?


You may also like

Honeywell TC-IAHI61 High-Level Analog Input ModuleHoneywell TC-IAHI61 High-Level Analog Input ModuleHoneywell TC-IAHI61 High-Level Analog Input Module
Honeywell TC-IAHI61 High-Level Analog Input Module
Honeywell TC-IAHI61 High-Level Analog Input Module
Honeywell TC-IAHI61 High-Level Analog Input Module

Honeywell TC-IAHI61 High-Level Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : TC-IAHI61

PRODUCT TYPE : High-Level Analog Input Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-level analog signal acquisition in Honeywell Experion PKS and TDC 3000 DCS platforms, the Honeywell TC-IAHI61 (TC-IAHI61 High-Level Analog Input Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model TC-IAHI61
Brand Honeywell
Origin USA
Weight Approx. 1.5 kg
Dimensions Not specified
Operating Temp 0 deg C to 60 deg C
Power Consumption 4.1 W maximum
Module Type High-Level Analog Input (HLAI) Module
Compatible Systems Honeywell Experion PKS, TDC 3000 DCS
Number of Channels 16 independent analog input channels
Input Signal (Voltage) +/-10.25 V, 0 to 10.25 V, 0 to 5.125 V
Input Signal (Current) 4-20 mA, 0 to 20.5 mA via internal 250 ohm resistor
A/D Conversion Resolution 16-bit
Module Update Rate 250 ms
Sampling Capability Up to 1 kHz transient capture rate
Voltage Input Impedance Greater than 1.0 Mohm
Current Input Impedance 249 ohm nominal
Channel Bandwidth 20 Hz (-3 dB)
RFI Immunity Less than 2% error of range at 10 V/m, 27 to 1000 MHz
Isolation Voltage 2550 VDC for 1 second (User to System)
Compatible Terminal Block TC-TBCH 36-position terminal block

Process Signal Isolation and 4-20 mA HART Loop Protocol

The Honeywell TC-IAHI61 integrates high-level analog measurement circuits for direct connection to field transmitters across 16 independent channels. The input architecture provides channel-to-channel isolation and galvanic user-to-system isolation up to 2550 VDC to prevent common-mode electrical interference and ground loop cross-talk. Signal processing paths support full 4-20 mA HART loop protocol compatibility at the physical interface, converting field voltage and current loops into 16-bit digital values while maintaining signal integrity across the Experion PKS and TDC 3000 backplane interfaces. Integrated diagnostic circuits perform open-circuit detection to identify field wiring faults in real time.

Frequently Asked Questions

Q: Does the TC-IAHI61 support mixed analog input types on the same module?

A: Yes, each of the 16 channels can be configured independently for either voltage ranges (+/-10.25 V, 0-10.25 V, 0-5.125 V) or current signals (4-20 mA, 0-20.5 mA).

Q: What isolation voltage level does the TC-IAHI61 provide?

A: The module features user-to-system electrical isolation rated and tested at 2550 VDC for 1 second.

Q: Which terminal block is required for external field wiring connections?

A: The module directly interfaces with the Honeywell TC-TBCH 36-position terminal block assembly.

Field Installation Guidelines

  1. Confirm electrostatic discharge (ESD) prevention measures are in place and wear a grounded wrist strap prior to handling the module.
  2. Insert the module into the designated slot of the Honeywell Experion PKS or TDC 3000 chassis until the backplane connectors fully seat.
  3. Align and attach the TC-TBCH 36-position terminal block, securing all mounting hardware to ensure continuous contact.
  4. Route field analog signal cables through low-voltage cable channels, keeping them separate from AC power and high-voltage switching lines.
  5. Connect cable shield drain wires directly to the designated enclosure earth grounding bar in accordance with site grounding standards.
  6. Verify field loop polarity and ensure transmitter output range settings match the configured voltage or current parameters before energizing the loop.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more
Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Industrial automation relies on continuous operational stability to prevent catastrophic downtime and financial loss. While standard dictionary definitions treat redundancy as superfluous, industrial engineers consider redundant control architectures indispensable for high-availability systems. Implementing backup hardware ensures seamless takeover during primary equipment failures, protecting critical infrastructure across manufacturing and process industries.

Read more