Skip to content

What are you looking for?


You may also like

Honeywell MC-PLAM02 51304362-150/51120493-101 Low Level Analog Multiplexer ProcessorHoneywell MC-PLAM02 51304362-150/51120493-101 Low Level Analog Multiplexer ProcessorHoneywell MC-PLAM02 51304362-150/51120493-101 Low Level Analog Multiplexer Processor
Honeywell MC-PLAM02 51304362-150/51120493-101 Low Level Analog Multiplexer Processor
Honeywell MC-PLAM02 51304362-150/51120493-101 Low Level Analog Multiplexer Processor
Honeywell MC-PLAM02 51304362-150/51120493-101 Low Level Analog Multiplexer Processor

Honeywell MC-PLAM02 51304362-150/51120493-101 Low Level Analog Multiplexer Processor


Only 10 left - Selling fast

PRODUCT SKU : MC-PLAM02 51304362-150 51120493-101

PRODUCT TYPE : Analog Multiplexer Processor

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell MC-PLAM02 (PN: 51304362-150 / 51120493-101) operates as a high-density Low Level Analog Multiplexer (LLMux) within the Honeywell Distributed Control System architecture. This processor specializes in capturing sensitive millivolt data from Thermocouples (TC) and Resistance Temperature Detectors (RTDs). We supply this unit in 100% brand-new, original factory condition, ensuring the signal precision required for critical thermal process loops. By aggregating multiple sensor inputs into a single stream, the MC-PLAM02 optimizes hardware efficiency while maintaining microvolt-level accuracy.

Technical Specifications

Parameter Technical Data
Model Number MC-PLAM02
Part Numbers 51304362-150 / 51120493-101
Input Type Low Level Analog (TC, RTD, mV)
Physical Dimensions 15.1 cm x 3.8 cm x 13.0 cm
Unit Weight 0.6 kg
Mounting Configuration High-Density I/O Carrier
Condition 100% Brand New Original

Engineering Advantages

  • Suppresses Thermal EMF: The module utilizes high-grade solid-state switching to eliminate parasitic voltage offsets. This hardware-level suppression ensures that the DCS receives pure thermocouple data without the interference typical of mechanical relay multiplexing.

  • Eliminates Industrial Noise: Onboard active filtering circuitry rejects 50/60 Hz power line interference and electromagnetic transients. This allows the processor to deliver stable readings even when installed near high-voltage motor starters or variable frequency drives.

  • Maximizes Cabinet Density: The slim 3.8 cm profile enables engineers to pack more temperature monitoring points into a standard Honeywell I/O rack. This reduces the total number of required cabinets and lowers the overall hardware footprint in the control room.

  • Automates Cold Junction Compensation: When paired with the Field Termination Assembly (FTA), the MC-PLAM02 tracks ambient temperature fluctuations in real-time. It automatically applies compensation values to thermocouple inputs, ensuring measurement stability despite shifting cabinet temperatures.

  • Streamlines Signal Aggregation: The processor multiplexes diverse low-level inputs into a single data stream. This architecture replaces the need for expensive, individual analog input channels for every sensor, significantly lowering the cost per point in high-count temperature monitoring applications.

FAQs

  • Does this unit come with a factory warranty?

    Yes. We provide the MC-PLAM02 in 100% brand-new, original condition, complete with full factory-standard reliability and packaging.

  • Can the MC-PLAM02 handle both RTD and Thermocouple signals simultaneously?

    The processor supports various low-level millivolt inputs. However, ensure that your Field Termination Assembly (FTA) and software configuration match the specific sensor types connected to the multiplexer stream.

  • How does this module improve accuracy compared to standard AI cards?

    Unlike standard analog input cards, the LLMux processor utilizes specialized circuits designed specifically for the microvolt range. This reduces the signal-to-noise ratio issues commonly found when trying to measure sensitive temperature sensors through general-purpose hardware.

  • What are the primary installation requirements?

    The module slides directly into a standard Honeywell I/O carrier. Engineers must ensure the seat is secure and the locking mechanisms engage to prevent signal interruption caused by industrial vibration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more