PRODUCT SKU : MC-GA1H13 51304718-175

PRODUCT TYPE : Analog Input FTA

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The MC-GAIH13 (51304718-175) is a high-performance Field Termination Assembly (FTA) engineered specifically for Honeywell Experion PKS and TDC 3000 control systems. This 16-channel interface is designed to support High-Level Analog Input (HLAI) and Smart Transmitter Interface (STI) signals, providing a secure bridge between field instrumentation and the system's I/O processors. A defining feature of this assembly is its integrated galvanic isolation, which protects the controller from high-voltage transients and eliminates ground loop interference. The MC-GAIH13 is fully conformally coated, making it resilient against atmospheric corrosion in harsh industrial sectors like oil and gas or chemical processing.

Technical Specifications

  • Model Identification: MC-GAIH13

  • Part Number: 51304718-175

  • Functional Category: HLAI / STI Field Termination Assembly

  • Channel Density: 16 Independent Input Channels

  • Isolation Type: Galvanic / Intrinsically Safe (GI/IS) Support

  • System Connectivity: Redundant I/O Processor Support

  • Terminal Interface: Compression-style screw terminals

  • Environmental Protection: Full Conformal Coating

  • Physical Profile: Size B Assembly (12 inches / 307 mm)

  • Shipping Mass: 2.0 kg

Galvanic Isolation and Safety

The MC-GAIH13 (51304718-175) is optimized for applications where signal integrity and hardware protection are paramount. The galvanic isolation barrier ensures that even in the event of field-side electrical failure, the sensitive internal logic of the control system remains undamaged. By supporting both standard analog and smart transmitters, the assembly offers flexibility for plant-wide upgrades. Furthermore, its redundancy-capable architecture allows for dual I/O link connections, ensuring that process data remains available during a primary processor failover.

Frequently Asked Questions

  • What is the advantage of the MC-series over the standard MU-series?

    The MC-GAIH13 includes a conformal coating that safeguards the PCB against moisture, dust, and corrosive gases. This makes it far more durable for long-term deployment in non-climate-controlled environments compared to the non-coated MU-equivalent.

  • Does this FTA support redundant wiring?

    Yes, the MC-GAIH13 (51304718-175) features ports for two I/O link cables, allowing it to interface simultaneously with both primary and secondary I/O processors for maximum system uptime.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more