Skip to content

What are you looking for?


You may also like

Honeywell 620-0036 AC Power Supply ModuleHoneywell 620-0036 AC Power Supply ModuleHoneywell 620-0036 AC Power Supply Module
Honeywell 620-0036 AC Power Supply Module
Honeywell 620-0036 AC Power Supply Module
Honeywell 620-0036 AC Power Supply Module

Honeywell 620-0036 AC Power Supply Module


Only 10 left - Selling fast

PRODUCT SKU : 620-0036

PRODUCT TYPE : Power Supplies

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 620-0036 (620-0036 AC Power Supply Module) serves as the primary AC Power Supply utilized to execute power conversion and distribution across IPC 620 control platforms. This module performs the rectification and regulation of line-side AC inputs into stable DC power levels required for backplane logic and I/O module excitation.

Hardware Specifications

Parameter Specification
Model 620-0036
Brand Honeywell
Origin USA
Weight 1.78 kg (3.92 lbs)
Dimensions Not specified
Operating Temp Standard industrial ambient range
Power Consumption 115/230 VAC input; 2/1 A
Frequency 47-63 Hz

Channel-to-Channel Isolation and Power Distribution

The 620-0036 module maintains channel-to-channel isolation between the AC mains and the system DC bus to mitigate noise propagation. This isolation is required to preserve the signal integrity of the 4-20 mA HART loop protocol utilized by connected field devices. The power stage is engineered to provide a clean DC rail, essential for stable operation of processor circuits and auxiliary components. When configured in large-scale racks, proper grounding and cold junction compensation (CJC) strategies must be observed to prevent common-mode noise from affecting signal measurements throughout the system.

Frequently Asked Questions

Q: Does the 620-0036 support hot-swapping during rack operation?

A: No. Hot-swapping is not permitted in the IPC 620 system. All AC input power must be removed and the module de-energized before attempting to remove or install the module from the rack backplane.

Q: Can multiple 620-0036 modules be wired in parallel for increased current capacity?

A: No. Parallel configuration of these power supplies is not supported. Use a single supply module rated for the specific rack power requirements as defined by the I/O configuration map.

Field Installation Guidelines

  • Mounting: Secure the module into the rack chassis using all provided fastening points. Ensure the backplane connector is fully seated to prevent voltage drops at the DC output pins.
  • Grounding: The chassis of the 620-0036 must be connected to the system earth ground. Use low-impedance copper cable to ensure effective transient surge dissipation.
  • Wiring: Input AC lines must be separated from signal conduits to prevent electromagnetic interference. Adhere to all local electrical codes for wire sizing corresponding to the 2 A maximum input current.
  • Ventilation: Verify that air intake and exhaust paths are not obstructed. Excessive heat accumulation can trigger internal thermal protection, causing the module to shut down.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more