Honeywell 51301874-100 Thermocouple Low Energy Mux BoardHoneywell 51301874-100 Thermocouple Low Energy Mux BoardHoneywell 51301874-100 Thermocouple Low Energy Mux Board
Honeywell 51301874-100 Thermocouple Low Energy Mux Board
Honeywell 51301874-100 Thermocouple Low Energy Mux Board
Honeywell 51301874-100 Thermocouple Low Energy Mux Board

Honeywell 51301874-100 Thermocouple Low Energy Mux Board


Only 10 left - Selling fast

PRODUCT SKU : 51301874-100

PRODUCT TYPE : Multiplexer Boards

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for multiplexing high-density thermocouple signal channels in Honeywell process automation architectures, the Honeywell 51301874-100 (51301874-100 Thermocouple Low Energy Mux Board) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model 51301874-100
Brand Honeywell
Origin USA
Operating Temp -40 to +70 deg C
Power Consumption Passive multiplexer board operating on 24 VDC bus
Input Voltage 24 VDC
Output Voltage 24 VDC
Storage Temp -40 to +85 deg C
Channel Capacity Switches up to 16 thermocouple inputs
Thermocouple Types Type J, K, T, S, E, and R
System Interface Low Energy Process Interface Unit (LEPIU) CCFA

Cold Junction Compensation (CJC) & Channel Isolation

The multiplexer board routes up to 16 thermocouple sensor inputs directly into the Low Energy Process Interface Unit (LEPIU) CCFA assembly for precise signal linearization across Type J, K, T, S, E, and R thermocouple curves. High-grade board-level cold junction compensation (CJC) reference circuits correct for ambient thermal gradients across the field terminal termination zone. Integrated channel-to-channel isolation prevents ground loop current propagation and suppresses low-level millivolt signal interference during high-speed analog channel switching.

Frequently Asked Questions

Q: Which thermocouple sensor types can be processed by the 51301874-100 multiplexer board?

A: The board provides routing and linearization compatibility for Type J, K, T, S, E, and R thermocouples.

Q: What interface module does the 51301874-100 board connect with for analog processing?

A: The board switches millivolt signals directly to the Low Energy Process Interface Unit (LEPIU) CCFA assembly.

Q: What are the environmental operating temperature limits for cabinet installation?

A: The hardware operates continuously within ambient enclosure temperatures ranging from -40 deg C to +70 deg C.

Field Installation Guidelines

  1. De-energize the 24 VDC system power rail before inserting or removing the multiplexer board from the rack slot.
  2. Connect thermocouple lead wires to designated terminal points, observing polarity and using extension wires matching the specific thermocouple type.
  3. Secure all field wiring drain shields to the main panel earth ground bus bar to prevent common-mode noise corruption on millivolt inputs.
  4. Ensure CJC thermal sensors on the termination block remain unobstructed and free from localized heating sources.
  5. Inspect edge connectors for correct mechanical alignment before fully seating retaining fasteners.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Supervisory Control and Data Acquisition (SCADA) systems form the digital backbone of modern industrial automation. They collect critical field data, transmit signals across vast distances, and empower plant operators with real-time process visibility. Across modern infrastructures, SCADA solutions streamline centralized control and maintain continuous operational uptime.

Read more
Understanding OPC Servers in Modern Industrial Automation: Principles, Architecture, and Applications

Understanding OPC Servers in Modern Industrial Automation: Principles, Architecture, and Applications

In industrial automation, connecting physical hardware with high-level software remains a primary operational challenge. Factories utilize programmable logic controllers (PLCs), distributed control systems (DCS), human-machine interfaces (HMIs), and smart sensors from diverse vendors. These devices often speak different proprietary protocols. Open Platform Communications (OPC) servers solve this interoperability challenge by standardizing how data flows across factory networks.

Read more
Industrial Fiber Optic Cables: Principles, Connectors, and Fusion Splicing Techniques

Industrial Fiber Optic Cables: Principles, Connectors, and Fusion Splicing Techniques

Modern factory automation relies heavily on fiber optic cables for high-speed industrial data transmission. Fiber optic cables transmit light pulses instead of electrical signals, eliminating electromagnetic interference (EMI) risks completely. Each optical strand consists of a high-purity glass core surrounded by a protective cladding layer. The difference in refractive index between core and cladding enables total internal reflection. Protective resin buffers, Kevlar strength members, and rugged outer jackets safeguard delicate glass cores in harsh environments. Consequently, automation engineers prefer fiber backbones for reliable noise-free communication in industrial control systems.

Read more