Honeywell 51201298-290 Ground Cable Assembly
Honeywell 51201298-290 Ground Cable Assembly
Honeywell 51201298-290 Ground Cable Assembly

Honeywell 51201298-290 Ground Cable Assembly


Only 10 left - Selling fast

PRODUCT SKU : 51201298-290

PRODUCT TYPE : Grounding Cables

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for low-impedance protective earth and system reference grounding across Honeywell TDC 3000 and Experion PKS cabinets, the Honeywell 51201298-290 (51201298-290 Ground Cable) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model 51201298-290
Brand Honeywell
Origin USA
Weight 0.35 kg
Dimensions Standard Cabinet Bonding Strap Length
Operating Temp -40 deg C to 85 deg C
Power Consumption Passive Conductive Component
Conductor Material Multi-strand flexible copper braid / conductor
Termination Type Heavy-duty ring lug connectors
Insulation Type Flame-retardant protective sleeve
Current Capacity Low-impedance fault current bonding path
System Compatibility Honeywell TDC 3000, Experion PKS

Channel Isolation and HART Loop Protocol Interoperability

The Honeywell 51201298-290 ground cable bonds system chassis, backplanes, and shield bus bars directly to cabinet protective earth to prevent floating ground potentials. When deployed near field termination assemblies (FTAs) carrying sensitive 4-20 mA HART loop protocol communications, this low-impedance connection drains stray capacitive currents and common-mode noise. Equalizing ground potential across DCS enclosures eliminates ground loops that cause signal offsets or communication frame errors on analog I/O channels.

Frequently Asked Questions

Q: Does the 51201298-290 ground cable require periodic electrical continuity testing?

A: Yes, ground bonding resistance should be periodically verified using a low-resistance ohmmeter to ensure the path to earth remains below 0.1 ohms.

Q: Can this cable be used for both safety earth and instrument signal shield grounding?

A: The cable is designed for low-impedance cabinet bonding; follow system engineering guidelines to ensure safety earth and isolated instrument ground paths remain properly connected at designated single-point bus bars.

Field Installation Guidelines

  1. Ensure cabinet power is isolated and de-energized prior to establishing or modifying ground bonding connections.
  2. Clean contact surfaces on the grounding bar or chassis backplane to bare metal to ensure low contact resistance.
  3. Secure terminal ring lugs using appropriate star washers and torque threaded fasteners to cabinet structural specification.
  4. Route the grounding cable along designated cabinet grounding paths, keeping runs as short and straight as possible.
  5. Verify zero resistance to protective earth prior to re-energizing control equipment.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more