Skip to content

What are you looking for?


You may also like

Honeywell 100 Base-T Industrial Ethernet Cable | 51305482-505Honeywell 100 Base-T Industrial Ethernet Cable | 51305482-505Honeywell 100 Base-T Industrial Ethernet Cable | 51305482-505
Honeywell 100 Base-T Industrial Ethernet Cable | 51305482-505
Honeywell 100 Base-T Industrial Ethernet Cable | 51305482-505
Honeywell 100 Base-T Industrial Ethernet Cable | 51305482-505

Honeywell 100 Base-T Industrial Ethernet Cable | 51305482-505


Only 10 left - Selling fast

PRODUCT SKU : 51305482-505

PRODUCT TYPE : Industrial Ethernet Cables

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Hardware Specifications

Parameter Specification
Model 51305482-505
Brand Honeywell
Origin USA
Dimensions 5 meters (LAN B version)
Operating Temp -40 to +85 deg C
Power Consumption Passive wiring component
Component Type Industrial Ethernet Cable / 100 Base-T LAN Cable
Conductor Material Copper
Conductor Gauge 20 AWG
Insulation Material PVC
Rated Voltage 300-600 V
Rated Current 5 A
Shielding Multi-conductor overall industrial shielding

FOUNDATION Fieldbus / Profibus PA Connectivity

The 51305482-505 100 Base-T Ethernet cable establishes reliable physical layer links between local control network nodes and upper-level DCS architectures. When routed adjacent to field instrumentation buses utilizing FOUNDATION Fieldbus or Profibus PA protocol configurations, the high-density shielding layer attenuates industrial electromagnetic noise and cross-talk.

This signal integrity prevents packet corruption and latency spikes across the TPNB LAN B network, ensuring continuous telemetry synchronization between system controllers and process network gateways.

Frequently Asked Questions

Q: What network interface protocols are supported by the 51305482-505 cable assembly?

A: The cable assembly is engineered for 100 Base-T Ethernet communications and supports data exchange across Honeywell TPNB LAN B networks.

Q: What conductor size and voltage rating are specified for this Ethernet cable?

A: The assembly utilizes 20 AWG multi-conductor copper wiring rated for operation between 300 V and 600 V.

Q: Can this industrial Ethernet cable withstand harsh cabinet thermal environments?

A: Yes, the cable jacket and PVC insulation are specified for continuous operation across an extended temperature range of -40 to +85 deg C.

Field Installation Guidelines

  • De-energize connected network interface cards or switch ports before mating or unmating Ethernet connectors.
  • Ensure maximum tensile load and minimum bending radius specifications are respected during conduit pulling to protect the 20 AWG conductor core.
  • Route the industrial Ethernet cable along dedicated communication wireways, maintaining separation from high-voltage AC power distribution.
  • Connect the cable shield drain directly to the cabinet protective earth (PE) grounding bar to ensure effective high-frequency noise suppression.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more