Skip to content

What are you looking for?


You may also like

General Electric DS200QTBAG1A RST Termination BoardGeneral Electric DS200QTBAG1A RST Termination BoardGeneral Electric DS200QTBAG1A RST Termination Board
General Electric DS200QTBAG1A RST Termination Board
General Electric DS200QTBAG1A RST Termination Board
General Electric DS200QTBAG1A RST Termination Board

General Electric DS200QTBAG1A RST Termination Board


Only 10 left - Selling fast

PRODUCT SKU : DS200QTBAG1A

PRODUCT TYPE : Terminal Boards

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

 

The GE DS200QTBAG1A, also cataloged as the DS200QTBA Termination Module, operates as a dedicated hardware component for signal termination and bus interface management within Mark V turbine control system platforms.

Hardware Specifications

Parameter Specification
Model DS200QTBAG1A
Brand General Electric
Origin USA
Operating Temp Standard industrial range
Terminal Blocks 2 blocks, 72 terminals each (144 total)
Connectors 1 x 40-pin (JFF), 1 x 34-pin (JGG), 1 x Serial (JRS), COREBUS (JAI, JAJ), I/O (JEE)

Industrial Control and Firmware Flash Compatibility

The DS200QTBAG1A serves as a high-density termination point for Mark V turbine control signal routing. It facilitates deterministic data exchange via dedicated COREBUS connectors (JAI, JAJ), ensuring synchronized communication across the control architecture. Signal conditioning and I/O distribution are managed through the JFF connector for LVDT/R and servo output signals, the JGG connector for TCQC interface signals, and the JEE connector for STCA board I/O. The module supports I/O density scaling through two 72-terminal blocks, providing 144 total termination points for field instrumentation. Firmware flash compatibility is not applicable, as signal paths are established through fixed board traces; however, the board architecture supports integration with the Mark V Speedtronic logic platform.

Frequently Asked Questions

Q: Can the DS200QTBAG1A be used to replace the base DS200QTBA board?

A: The G1A revision includes functional modifications. Verify system compatibility and terminal assignment mappings against the specific Mark V control cabinet documentation before substituting the base parent module.

Q: Are the serial (JRS) and COREBUS connectors compatible with standard cable assemblies?

A: The connectors follow specific GE Mark V pinout standards. Ensure cables are verified against the instructional manual pin-out definitions before connection to avoid damage to the transceiver circuitry on the processor boards.

Field Installation Guidelines

  1. Ensure the control cabinet is de-energized prior to board installation to prevent electrical damage to the COREBUS interface components.
  2. Verify all field wiring connections against the system termination drawing. Given the high-density layout (144 terminals), use insulated ferrules to prevent short-circuiting between adjacent terminals.
  3. Secure the module mounting screws to the cabinet backplane to ensure proper grounding and mechanical stability.
  4. Route signal cables, particularly those for LVDT/R and serial monitor signals, through dedicated conduits or cable trays to minimize electromagnetic interference.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Modern control systems rely heavily on seamless interprocess communication to exchange operational data between software programs. Microsoft first introduced the Dynamic Data Exchange (DDE) protocol in 1987 to enable real-time data sharing. In factory automation, DDE served as an early bridge between control software and Windows desktop applications. Therefore, understanding DDE mechanics provides crucial insights into how legacy industrial networks established software-level connectivity.

Read more
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more