PRODUCT SKU : IC200PNS001

PRODUCT TYPE : Network Interface Unit

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The GE Fanuc VersaMax IC200PNS001 Remote I/O PROFINET Network Interface Unit enables seamless integration of VersaMax systems into PROFINET networks. Supporting multiple topologies and configurable update rates, it provides reliable communication and flexible connectivity for industrial automation environments.

Technical Specifications

  • Model / Part Number IC200PNS001

  • Manufacturer GE Fanuc Emerson

  • Product Line VersaMax

  • Product Type Remote I/O PROFINET Network Interface Unit

  • Weight 0.75 lbs (0.34 kg)

  • Power Consumption 0.60 A at 5 VDC

  • Supported Protocols PROFINET Slave, Version 2.2 Class A IO-Device

  • Software Requirement Proficy Machine Edition Version 7.0 or later

  • Topologies Supported Linear, Star, Ring (redundant)

  • Ports Two RJ-45 connectors

  • Transmission Speed 10/100 Mbps

  • Maximum Cable Distance 100 m per segment

  • I/O Capacity 2880 bytes total (1440 bytes input, 1440 bytes output)

  • Diagnostic Data 32 input status bits, 32 output control bits

  • I/O Modules Supported Up to 8 modules

  • Mounting DIN rail

  • Dimensions Height 132 mm (5.2 in), Width 134 mm (5.28 in)

  • Operating Temperature Range 0–60°C ambient air without fan

  • RoHS Compliance Yes

  • Compatible Controllers Series 90-70, PACSystems RX7i, PACSystems RX3i

  • I/O Update Rate Configurable: 1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms, 64 ms, 128 ms, 256 ms, 512 ms

Application Scenarios

  • Integration of VersaMax systems into PROFINET-based automation networks

  • Multi-module communication setups requiring redundancy and scalability

  • Industrial environments needing configurable update rates for precise control

FAQ

Q: How many I/O modules can the IC200PNS001 support?  A: Up to 8 modules are supported.

Q: What topologies are available?  A: Linear, star, and redundant ring configurations are supported.

Q: What is the maximum cable distance per segment?  A: 100 meters per segment.

Q: Which controllers are compatible?  A: Series 90-70, PACSystems RX7i, and PACSystems RX3i.

Comparison with Similar Models

  • IC200PNS001: PROFINET interface, 8 modules, configurable update rates

  • IC200PBI001: Profibus interface, supports 64 I/O modules, 9-pin D-sub connector

  • IC200DBI001-DA: DeviceNet interface, supports 64 nodes and 8 modules

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more