Skip to content

What are you looking for?


You may also like

GE Fanuc VersaMax IC200ALG326 | 8-Channel 15-Bit Analog Output ModuleGE Fanuc VersaMax IC200ALG326 | 8-Channel 15-Bit Analog Output ModuleGE Fanuc VersaMax IC200ALG326 | 8-Channel 15-Bit Analog Output Module
GE Fanuc VersaMax IC200ALG326 | 8-Channel 15-Bit Analog Output Module
GE Fanuc VersaMax IC200ALG326 | 8-Channel 15-Bit Analog Output Module
GE Fanuc VersaMax IC200ALG326 | 8-Channel 15-Bit Analog Output Module

GE Fanuc VersaMax IC200ALG326 | 8-Channel 15-Bit Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : IC200ALG326

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The GE Fanuc VersaMax IC200ALG326 Analog Output Module is a compact and reliable solution for current loop control in automation systems. With eight single-ended channels, high resolution, and configurable output ranges, it provides flexibility and precision for industrial applications.

Technical Specifications

  • Model / Part Number IC200ALG326

  • Manufacturer GE Fanuc Emerson

  • Product Line VersaMax

  • Type Output Module

  • Weight 0.44 lbs (0.20 kg)

  • Channels 8 single-ended outputs

  • LED Indicators Two status LEDs for module operation

  • Isolation 250 VAC continuous, 1500 VAC for 1 minute

  • Backplane Current Consumption 5 V output, 50 mA maximum

  • Current Range Default 4–20 mA, configurable to 0–20 mA via jumper

  • Resolution 15-bit precision for fine signal control

  • Update Rate Maximum 15 ms

  • Output Default Configurable to meet system requirements

Application Scenarios

  • Multi-channel current loop control in distributed automation systems

  • Integration with sensors, actuators, and transmitters requiring precise current outputs

  • Industrial environments where isolation and configurable ranges are critical

FAQ

Q: Can the output range be changed from 4–20 mA to 0–20 mA?  A: Yes, the module allows configuration via jumper settings.

Q: How many channels are available?  A: The IC200ALG326 provides eight single-ended current output channels.

Q: What level of isolation does the module provide?  A: It offers 250 VAC continuous isolation and 1500 VAC for one minute, ensuring safe operation in industrial environments.

Comparison with Similar Models

  • IC200ALG320: 4 channels, current output (4–20 mA), 12-bit resolution, faster update rate (0.3 ms)

  • IC200ALG322: 4 channels, voltage output (0–10 V), 12-bit resolution

  • IC200ALG326: 8 channels, current output (4–20 mA or 0–20 mA), 15-bit resolution, 15 ms update rate

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more