PRODUCT SKU : FC-SDO-0824M

PRODUCT TYPE : Safe Digital Output Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Honeywell FC-SDO-0824 Safe Digital Output Module is designed for secure and reliable switching in industrial control and safety systems. With eight solid-state digital output channels, it provides fail-safe operation and short-circuit protection, ensuring dependable performance in demanding environments. Its compact design and efficient power requirements make it suitable for integration into distributed control architectures.

Key Technical Specifications

  • Manufacturer: Honeywell

  • Model Number: FC-SDO-0824

  • Product Type: Safe Digital Output Module

  • Space Requirements: 4 TE, 3 HE (equivalent to 4 HP, 3U)

  • Power Requirements:

    • 5 VDC: 25 mA

    • 24 VDC (Internal): 25 mA

    • 24 VDC (External): 70 mA (without output load)

  • Output Channels: 8

  • Output Type: 24 VDC solid-state source, short-circuit proof

  • Maximum Current per Channel: 550 mA

  • Maximum Lamp Load: 120 mA (2.9 W)

  • Maximum Load Capacitance: 1 pF

  • Voltage Drop: < 2.0 VDC at 500 mA

  • Off Current: < 0.1 mA

  • WDG Input Current: 8 mA

Features

  • Fail-Safe Outputs: Solid-state design ensures reliable switching.

  • Short-Circuit Proof: Continuous protection for safe operation.

  • Compact Size: Optimized for cabinet integration with minimal space requirements.

  • High Current Capacity: Supports up to 550 mA per channel.

  • Low Voltage Drop: Maintains efficiency under load conditions.

Application Scenarios

  • Process Safety Systems: Drives alarms, solenoids, and shutdown devices.

  • Power Generation: Provides fault-tolerant outputs in distributed control systems.

  • Chemical & Petrochemical Plants: Ensures safe switching in hazardous environments.

  • Industrial Automation: Supports reliable digital output control in complex projects.

FAQ

Q: How many output channels does the FC-SDO-0824 provide?  A: It supports 8 digital output channels.

Q: What is the maximum current per channel?  A: Each channel can deliver up to 550 mA.

Q: Is the module short-circuit proof?  A: Yes, it includes continuous short-circuit protection.

Q: What is the typical lamp load supported?  A: Up to 120 mA (2.9 W).

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more