Product Description

The Honeywell FC‑PDB‑ARTF05 A.R.T Power Distribution Module is a specialized component within the Safety Manager system, designed to provide stable low‑voltage power distribution with integrated fuse protection. Its compact design and compliance with DIN rail standards make it suitable for installation in safety‑critical automation environments.

Technical Specifications

  • Model / Type Number: FC‑PDB‑ARTF05

  • Manufacturer: Honeywell

  • Type: Safety Manager A.R.T Module

  • Power Supply Capacity:

    • 5V‑1: Maximum 16 A

    • 5V‑2: Maximum 16 A

  • Fuse Rating: 4 A (Blade type, 5 × 19 mm)

  • Voltage Rating (DC): 32 V

  • Maximum Output Current per Fuse: 2.8 A

  • Connectors:

    • 5V‑x: 4‑position action pin header

    • WdPx.y: 3‑pole pin header

  • Physical Dimensions:

    • Length: 234 mm (9.21 in)

    • Width: 109 mm (4.29 in)

    • Height: 68 mm (2.68 in)

  • DIN EN Rail Compatibility: TS32 / TS35 × 7.5

  • Required Rail Length: 235 mm (9.25 in)

  • Weight: Approx. 0.7 kg

  • Warranty: 12 months standard coverage

Key Features

  • High Current Handling: Dual 5 V channels supporting up to 16 A each

  • Integrated Fuse Protection: Safeguards circuits with 4 A blade fuses

  • Compact DIN Rail Mounting: Fits standard TS32 and TS35 rails

  • Reliable Distribution: Ensures stable low‑voltage supply across connected modules

  • Industrial Durability: Designed for long‑term use in demanding environments

Application Scenarios

  • Power distribution in Honeywell Safety Manager systems

  • Industrial automation requiring reliable low‑voltage supply

  • Safety‑critical process control environments

  • Modular installations with DIN rail mounting requirements

FAQ

Q: What is the maximum current supported by each fuse?  A: Each fuse supports up to 2.8 A output current.

Q: Can the FC‑PDB‑ARTF05 be used with non‑Honeywell systems?  A: It is optimized for Honeywell Safety Manager platforms; compatibility with other systems depends on connector and voltage requirements.

Q: How does this module differ from standard distribution blocks?  A: Unlike generic blocks, it integrates fuse protection, supports higher current loads, and is certified for use in safety‑critical systems.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more