Skip to content

What are you looking for?


You may also like

EtherNet/IP to PROFIBUS DP Gateway 5204-DFNT-PDPM | ProsoftEtherNet/IP to PROFIBUS DP Gateway 5204-DFNT-PDPM | ProsoftEtherNet/IP to PROFIBUS DP Gateway 5204-DFNT-PDPM | Prosoft
EtherNet/IP to PROFIBUS DP Gateway 5204-DFNT-PDPM | Prosoft
EtherNet/IP to PROFIBUS DP Gateway 5204-DFNT-PDPM | Prosoft
EtherNet/IP to PROFIBUS DP Gateway 5204-DFNT-PDPM | Prosoft

EtherNet/IP to PROFIBUS DP Gateway 5204-DFNT-PDPM | Prosoft


Only 10 left - Selling fast

PRODUCT SKU : 5204-DFNT-PDPM

PRODUCT TYPE : Master Gateway

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview
The Prosoft 5204-DFNT-PDPM (Version 2.45, OS 2.41) is a versatile EtherNet/IP to PROFIBUS DPV1 master gateway designed to integrate PROFIBUS DP slave devices into industrial automation systems. It enables seamless communication between EtherNet/IP networks and PROFIBUS DP devices, supporting both client and server communication modes. The compact DIN-rail mount design ensures easy installation in control cabinets while maintaining robust connectivity and performance.

Technical Specifications

  • Brand / Model: Prosoft 5204-DFNT-PDPM

  • Communication Type: EtherNet/IP to PROFIBUS DPV1 Master Gateway

  • EtherNet/IP Support: Explicit Messaging, 100/1000-word data table file size

  • PROFIBUS DPV1 Support: Up to 125 slave devices, 1536 bytes I/O (768 words), baud rates up to 12 Mbps

  • Hardware Requirements: Power 24 VDC (range 18–32 VDC), Max current 500 mA

  • Operating Temperature: -20°C to 50°C

  • Physical Dimensions: 5.20 in (H) x 2.07 in (W) x 4.52 in (D)

  • Mounting Style: DIN-rail

  • PROFIBUS Port: Configurable DB9F connector

  • Protocol Support: ProLinx Protocol for seamless EtherNet/IP integration

  • Version: Firmware 2.45, OS 2.41

Applications

  • Integration of PROFIBUS DP slave devices into EtherNet/IP-based industrial networks

  • Gateway solution for factory automation, process control, and distributed systems

  • Ideal for upgrading legacy PROFIBUS devices to EtherNet/IP communication

FAQ

  • Q: How many PROFIBUS DP slave devices can the gateway support?
    A: Up to 125 slaves with 1536 bytes of I/O

  • Q: What EtherNet/IP features are supported?
    A: Explicit Messaging with 100/1000-word data table support

  • Q: Can it be mounted on a standard DIN-rail?
    A: Yes, the unit is DIN-rail mountable for easy installation

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more