PRODUCT SKU : VE4002S1T2B6

PRODUCT TYPE : Digital I/O Card

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for discrete signal output in DeltaV I/O subsystems, the Emerson VE4002S1T2B6 (VE4002S1T2B6) Discrete Output Card provides direct physical/electrical execution of 32-channel high-side switching.

Hardware Specifications

Parameter Specification
Model VE4002S1T2B6
Brand Emerson
Origin USA
Weight Not specified
Dimensions 40-pin connector form factor
Operating Temp -40 deg C to +70 deg C
Power Consumption 100 mA (typical); 150 mA (maximum)
Output Voltage 24 VDC (High-Side)
Output Rating 1.0 A per channel; 3.0 A max per interface
Off-State Leakage < 1.2 mA (maximum)

Process Control: Channel-to-Channel Isolation

The VE4002S1T2B6 incorporates optical isolation for each of its 32 output channels, ensuring galvanic separation from the system backplane. This configuration is factory-tested to 1500 VDC to prevent electrical interference and protect the controller bus from field-side voltage spikes or short-circuit events. By isolating each channel, the module maintains signal determinism even in complex control loops where localized field faults might otherwise propagate across the output interface. This architecture is integrated with the 40-pin mass termination block to facilitate organized wiring while maintaining the integrity of the isolation barriers between individual field output circuits.

Frequently Asked Questions (FAQ)

Q: What is the maximum current capacity for the output interface?

A: The card is rated for 1.0 A per channel, with a cumulative maximum of 3.0 A per interface block. Exceeding these current limits will result in thermal stress on the output drivers and potentially trigger protective shutdown sequences.

Q: Does the module support hot-swapping?

A: Yes. The VE4002S1T2B6 is designed for hot-swapping within the M-Series I/O carrier. Ensure the control system configuration is updated or the point is set to a safe state before physical extraction to avoid unexpected equipment activation.

Field Installation Guidelines

  • Mounting: Secure the 40-pin mass termination block to the M-series carrier. Verify that the alignment keys match the I/O slot to ensure correct pin engagement with the backplane.

  • Wiring: Utilize properly rated cabling for the field output circuits. Because this module performs high-side switching at 24 VDC, ensure all field loads are correctly referenced to the common return to avoid ground loop currents.

  • Grounding: The carrier system must be bonded to the main cabinet ground bus. Effective grounding is necessary to ensure the 1500 VDC isolation barrier remains functional against transient surges.

  • Testing: Perform a loop check by toggling outputs via the DeltaV workstation diagnostics. Ensure that off-state leakage remains below the 1.2 mA threshold to prevent ghost voltages on sensitive actuator inputs.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more
Architectural Selection and Scale Classification of PLC Systems in Industrial Automation

Architectural Selection and Scale Classification of PLC Systems in Industrial Automation

Selecting the correct control platform represents a foundational engineering decision in factory automation. System designers must carefully balance technical parameters against long-term operational requirements when implementing a Programmable Logic Controller (PLC). This article examines the critical evaluation metrics, physical scale classifications, and operational architectures of modern control systems.

Read more