Skip to content

What are you looking for?


You may also like

Emerson 5X00058G01 Analog Input ModuleEmerson 5X00058G01 Analog Input ModuleEmerson 5X00058G01 Analog Input Module
Emerson 5X00058G01 Analog Input Module
Emerson 5X00058G01 Analog Input Module
Emerson 5X00058G01 Analog Input Module

Emerson 5X00058G01 Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 5X00058G01

PRODUCT TYPE : Analog Input Modules

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for HART-enabled signal acquisition in Ovation process control systems, the Emerson 5X00058G01 (5X00058G01 Analog Input Module) provides direct physical execution of high-precision analog input monitoring and digital communication.

Hardware Specifications

Parameter Specification
Model 5X00058G01
Brand Emerson
Origin Manufacturer-defined
Weight 6.80 kg
Dimensions Standard Ovation module form factor
Operating Temp Industrial standard range
Power Consumption System-dependent load
Function HART-enabled Analog Input

4-20 mA HART Loop Protocol

The 5X00058G01 facilitates the acquisition of analog process variables while concurrently supporting the 4-20 mA HART loop protocol for device diagnostics and configuration. The module architecture ensures channel-to-channel isolation to protect the analog signal integrity from common-mode noise and ground loops in multi-channel configurations. Data conversion is performed to map the 4-20 mA input signal into a digital format suitable for controller processing. This integration allows for the seamless extraction of secondary variables and diagnostic data from field-mounted transmitters without disrupting the primary control loop.

Frequently Asked Questions

Q: Does the 5X00058G01 module support hot-swapping during active system operation?

A: The module is designed for hot-swap operations within the Ovation I/O rack. Before physical module removal, ensure that the corresponding I/O points are inhibited in the Ovation engineering software to prevent false process alarms or control interrupts.

Q: Are there limitations on the HART communication frequency supported by this module?

A: The module adheres to the HART protocol specification for data transmission superimposed on the analog signal. Verify that the field-side cabling and loop impedance are within the defined parameters for reliable HART communication to avoid packet loss during variable polling.

Field Installation Guidelines

  1. Verify that the I/O rack slot is prepared for installation and confirm the power to the module is inhibited if system policy mandates.
  2. Align the 5X00058G01 module with the backplane connectors and seat firmly to establish secure bus communication.
  3. Terminate signal conductors to the designated terminal block, ensuring proper wire gauge and polarity for all input channels.
  4. Utilize shielded twisted-pair cabling for all analog signal runs and ensure the cable shield is connected to the cabinet ground at a single point to mitigate electromagnetic interference.
  5. Confirm successful module detection via the Ovation HMI diagnostic interface and verify channel signal stability post-installation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
PLC vs. PAC: Navigating Selection in Modern Industrial Automation

PLC vs. PAC: Navigating Selection in Modern Industrial Automation

Selecting the right controller is a fundamental decision in industrial automation. While the lines between Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC) often blur, understanding their core architectural differences is essential for system reliability. Both controllers serve as the brain of control systems, yet their specific capabilities dictate their suitability for various factory automation tasks.

Read more
Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

The textile industry stands at a critical technological crossroads. Legacy operations must now embrace digital transformation to remain competitive in a global market. By integrating advanced industrial automation—ranging from PLC-controlled machinery to sophisticated AI-driven analytics—manufacturers can significantly boost productivity, minimize material waste, and elevate overall product quality.

Read more
Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

In the realm of industrial automation, the Programmable Logic Controller (PLC) serves as the brain of the factory floor. However, its true power is unlocked through robust communication protocols. These digital pathways ensure seamless data exchange between controllers, sensors, and enterprise-level management systems.

Read more