Product Details
The Emerson 396509-03-7, also cataloged as the 396509-03-7 Power Supply Module, operates as a dedicated hardware component for internal bus power conditioning and DC voltage distribution within ControlWave PLC platforms. The rack-mountable unit converts incoming 24 VDC primary power into regulated internal rail voltages, delivering up to 1000 mA output capacity through dedicated 7-position and dual 3-position terminal block assemblies.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 396509-03-7 |
| Brand | Emerson |
| Origin | USA |
| Weight | 0.39 kg (0.85 lbs) |
| Dimensions | Standard ControlWave rack slot envelope |
| Operating Temp | -40 to +70 deg C |
| Power Consumption | Self-powered input stage |
| Product Type | Power Supply Modules |
| System Platform | ControlWave PLC |
| Input Voltage | 24 VDC |
| Output Current | 1000 mA at 24 VDC |
| Mounting Type | Rack-mountable |
| Termination Assembly | One 7-position terminal block, two 3-position terminal blocks |
4-20 mA HART Loop Protocol and Channel Isolation
The power supply architecture incorporates galvanic isolation between the primary 24 VDC input supply, system backplane logic rails, and field termination interfaces to eliminate ground loop current paths. When supporting racks loaded with 4-20 mA HART loop protocol transceivers and analog field modules, the power stage filters high-frequency ripple and switching transients to prevent noise injection into sensitive current measurement loops. Integrated cold junction compensation reference stability and precise voltage regulation maintain analog conversion accuracy across cabinet ambient shifts from -40 to +70 deg C.
Frequently Asked Questions
Q: Can the 396509-03-7 power supply module be hot-swapped while the ControlWave rack is active?
A: No. Primary 24 VDC input power to the terminal blocks must be isolated before removing or inserting the module to prevent electrical arcing and backplane logic disruption.
Q: What is the total current capacity provided by the output stage?
A: The module supplies a regulated maximum output current of 1000 mA at 24 VDC to feed internal backplane circuits and connected terminal modules.
Q: How are external power cables physically interfaced to the module chassis?
A: Wiring connects directly through field-removable screw terminal blocks, utilizing one 7-position terminal block and two 3-position terminal blocks for discrete power routing.
Field Installation Guidelines
- De-energize the main 24 VDC feed and ensure all field circuit breakers are locked out prior to physical assembly.
- Align the module card guide edges with the targeted slot inside the ControlWave rack enclosure.
- Push the card firmly into the rack guide until the rear backplane connectors seat completely and secure all retention screws.
- Strip the 24 VDC supply conductors to specified length and insert them into the correct terminals on the 7-position and 3-position blocks.
- Tighten terminal block screws to standard industrial torque specifications to prevent high-resistance contact points.
- Connect the main system enclosure earth grounding wire directly to the rack ground lug before restoring 24 VDC input power.
Additional Information
- 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
- 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
- 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
- Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
- Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
- Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.