Skip to content

What are you looking for?


You may also like

DS200TCRAG1ACC | GE Mark V | Relay Output Termination BoardDS200TCRAG1ACC | GE Mark V | Relay Output Termination BoardDS200TCRAG1ACC | GE Mark V | Relay Output Termination Board
DS200TCRAG1ACC | GE Mark V | Relay Output Termination Board
DS200TCRAG1ACC | GE Mark V | Relay Output Termination Board
DS200TCRAG1ACC | GE Mark V | Relay Output Termination Board

DS200TCRAG1ACC | GE Mark V | Relay Output Termination Board


Only 10 left - Selling fast

PRODUCT SKU : DS200TCRAG1ACC

PRODUCT TYPE : Relay Output Termination Board

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The GE DS200TCRAG1ACC Relay Output Board, identified by the acronym TCRA, is a termination module designed for the Mark V control system. This board provides relay output interfacing, enabling reliable signal termination and control functions within turbine and drive applications. With multiple revisions available, the DS200TCRAG1ACC ensures backward compatibility with earlier versions, making it a dependable choice for legacy system maintenance.

Technical Specifications

  • Manufacturer: GE General Electric

  • Model Number: DS200TCRAG1ACC

  • Product Type: Relay Output Termination Board

  • Series: Mark V

  • Functional Acronym: TCRA

  • Functional Description: Relay Output Board

  • PCB Coating: Standard (Normal Coating)

  • Revision Quantity: 3 revisions available

  • Backward Compatibility: Supported with first two revisions

Key Features

  • Provides relay output termination for Mark V systems

  • Designed for turbine and drive control applications

  • Standard PCB coating for durability in industrial environments

  • Backward compatibility ensures seamless integration with earlier revisions

Application Scenarios

  • Turbine control systems requiring relay output interfacing

  • Drive and automation platforms using GE Mark V architecture

  • Legacy system maintenance and spare part replacement

FAQ

Q: What is the functional acronym for this board?  

A: TCRA, representing Relay Output functionality.

Q: How many revisions are available for the DS200TCRAG1ACC?  

A: Three revisions, with backward compatibility for the first two.

Q: What type of PCB coating is used?  

A: Standard coating suitable for typical industrial environments.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more