PRODUCT SKU : AAI135-H50/13S00

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The AAI135-H50/13S00 from Yokogawa is a high‑performance analog input module designed for distributed control systems. It provides 16 isolated input channels for acquiring 4–20 mA signals from field transmitters, ensuring precise and stable data acquisition in process automation environments.

This module supports HART communication, enabling advanced diagnostics and asset management. The suffix codes define its configuration: “H” indicates HART protocol support, “5” specifies no explosion protection, “0” denotes the basic type, and “/13S00” confirms the inclusion of a pressure clamp terminal block (ATI-00) for secure wiring.

Technical Specifications

  • Model / Order Number: AAI135-H50/13S00

  • Manufacturer: Yokogawa Electric Corporation

  • Type: Analog Input Module

  • Channels: 16 isolated analog inputs

  • Signal Range: 4–20 mA DC

  • Communication: HART protocol supported

  • Suffix Codes:

    • H = HART communication enabled

    • 5 = No explosion protection

    • 0 = Basic type

  • Optional Code: /13S00 = Supplied with pressure clamp terminal block (ATI-00)

  • Mounting: Rack‑mounted (FIO subsystem)

  • Weight: Approx. 2.0 kg

  • Application: Integration with CENTUM VP and ProSafe‑RS systems

Application Scenarios

  • Signal acquisition from transmitters in process industries

  • Safety‑critical monitoring in petrochemical, oil & gas, and power generation

  • Systems requiring HART communication for diagnostics and asset management

FAQ

Q: How many channels does the AAI135-H50/13S00 support?  A: It provides 16 isolated analog input channels.

Q: What does the /13S00 option mean?  A: It indicates the module is supplied with a pressure clamp terminal block (ATI-00).

Q: Is this module explosion‑proof?  A: No, the suffix “5” specifies that it is a non‑explosion protected type.

Q: Does the module support HART communication?  A: Yes, it includes HART protocol support for diagnostics and asset management.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more
Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Modern industrial automation heavily relies on Programmable Logic Controllers (PLCs) to drive factory floor efficiency. Over my 15 years as an industrial automation expert working with DCS, TSI, and control systems, I have seen PLCs evolve into the central nervous system of modern manufacturing. Selecting the right controller requires a deep understanding of PLC types based on physical size, hardware architecture, and power supply configurations.

Read more
Comprehensive Guide to PLC Types in Modern Industrial Automation

Comprehensive Guide to PLC Types in Modern Industrial Automation

Modern industrial automation relies on programmable logic controllers to govern critical factory operations. System integrators classify PLCs based on scale, hardware architecture, and power supply design. Understanding these core categories enables automation engineers to select the right control system architecture. Consequently, proper hardware selection optimizes performance while minimizing long-term operational costs.

Read more