Overview

The Honeywell CC-TAIX61 (Part No. 51307077-175) is an 8-channel analog input module designed for DeviceNet-enabled distributed control systems (DCS). It converts field analog signals into digital data that can be efficiently processed by control systems, ensuring precise and reliable monitoring of industrial processes.

Key Features

  • Supports 8 independent analog input channels for multi-sensor integration

  • DeviceNet communication protocol with 500 kbps data transfer rate

  • Accepts 0–10 VDC input signals for a variety of sensors

  • Compact and lightweight design for flexible installation in control panels

  • Operates on 24 VDC power supply for compatibility with standard industrial systems

Technical Specifications

  • Model Number: CC-TAIX61

  • Order Number: 51307077-175

  • Type: Analog Input Module

  • Communication Protocol: DeviceNet

  • Communication Speed: 500 kbps

  • Number of Channels: 8

  • Input Range: 0–10 VDC

  • Power Supply: 24 VDC

  • Module Dimensions: 96 × 76 × 25 mm

  • Weight: 0.3 kg

Application Scenarios

The CC-TAIX61 is ideal for:

  • Integrating multiple analog sensors into DeviceNet-based DCS

  • Monitoring voltage signals from process equipment

  • Applications requiring compact, modular analog input solutions

  • Upgrading or expanding Honeywell C300 or Experion control systems

FAQ

Q: How many input channels does the CC-TAIX61 support?
A: The module provides 8 analog input channels.

Q: Which communication protocol is used?
A: DeviceNet protocol at 500 kbps is supported.

Q: What is the input voltage range?
A: It supports 0–10 VDC analog signals.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more