Skip to content

What are you looking for?


You may also like

ANB10D-427/CU2T | Yokogawa CENTUM VP ESB Bus Node UnitANB10D-427/CU2T | Yokogawa CENTUM VP ESB Bus Node UnitANB10D-427/CU2T | Yokogawa CENTUM VP ESB Bus Node Unit
ANB10D-427/CU2T | Yokogawa CENTUM VP ESB Bus Node Unit
ANB10D-427/CU2T | Yokogawa CENTUM VP ESB Bus Node Unit
ANB10D-427/CU2T | Yokogawa CENTUM VP ESB Bus Node Unit

ANB10D-427/CU2T | Yokogawa CENTUM VP ESB Bus Node Unit


Only 10 left - Selling fast

PRODUCT SKU : ANB10D-427/CU2T

PRODUCT TYPE : ESB Bus Node Unit

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa ANB10D-427/CU2T serves as a high-availability I/O expansion node for the CENTUM VP Distributed Control System (DCS). This unit facilitates the interface between the Field Control Station (FCS) and various FIO modules via a dual-redundant Extended Serial Backplane (ESB) bus. By providing a synchronized communication path and redundant power architecture, it ensures that field data remains accessible even during hardware or cable faults. We supply this unit as 100% Brand New and Original, meeting the strict reliability requirements of modern process industries.

Part Number Breakdown: ANB10D-427/CU2T

Yokogawa defines the technical configuration of this node unit through a specific alphanumeric suffix logic:

Code Category Technical Specification
ANB10D Model Node Unit for Dual-Redundant ESB Bus
-4 Power Supply Dual-redundant power supply modules installed
2 Voltage 220 - 240 V AC power supply input
7 Configuration Standard hardware revision (Updated for R6.01+ standards)
/CU2T Option Connector Unit with Integrated Terminator for ESB Bus

Technical Specifications

The ANB10D-427/CU2T integrates robust electrical and mechanical parameters to manage high-density I/O configurations:

  • Bus Interface: Dual-redundant ESB Bus (Requires two ESB cables for full redundancy)

  • Power Input: 220 V to 240 V AC, 50/60 Hz

  • Redundancy: Supports dual-redundant power modules and dual-path bus communication

  • Expansion Capacity: Accommodates Yokogawa FIO (Field Input/Output) modules

  • Termination: Integrated /CU2T Connector Unit with internal electrical terminator

  • Net Weight: 10 kg

  • Mounting: 19-inch rack-mountable (Occupies 5U of rack space)

Engineering Advantages

The ANB10D-427/CU2T addresses critical plant floor challenges through superior hardware engineering:

  • Eliminate Signal Reflections: The integrated /CU2T option provides a built-in terminator within the connector unit. This eliminates the need for external terminating resistors at the end of the ESB bus chain, ensuring high-speed signal integrity and preventing data corruption caused by electrical echoes.

  • Hot-Swappable Power Redundancy: The -4 suffix indicates dual-redundant power supplies. This allows maintenance teams to replace a faulty power module while the unit remains live. The healthy module assumes the full load instantly, maintaining I/O visibility without interrupting the process.

  • Enhanced Bus Reliability: By supporting a dual-redundant ESB bus, the unit maintains 100% communication even if one physical bus cable is severed or a connector fails. This dual-path architecture provides the deterministic data flow required for safety-critical control loops.

  • Industrial-Grade Filtering: Engineered for 220-240V AC environments, the internal circuitry filters electromagnetic interference (EMI) and handles the voltage transients typical of heavy industrial grids, protecting sensitive FIO modules from electrical damage.

FAQs

  • When should I use the /CU2T option instead of /CU2N?

    Use the /CU2T (Terminator) for the node located at the physical end of the ESB bus chain to ensure proper electrical termination. For nodes in the middle of a daisy chain, use the /CU2N (Non-terminator) version.

  • Is the ANB10D-427 compatible with older CENTUM CS 3000 systems?

    Yes, this unit maintains backward compatibility with legacy CENTUM systems. However, its "7" revision code optimizes it for CENTUM VP R6.01 and later, providing improved thermal management and updated component longevity.

  • What mounting hardware is required for the 10 kg chassis?

    The unit fits standard 19-inch racks. We recommend using the provided M5 screws and insulation bushes. The insulation bushes are critical to prevent ground loops between the chassis and the rack frame, which can interfere with analog signal accuracy.

  • Does the unit include the FIO modules?

    No. The ANB10D-427/CU2T is the base node unit. You must order specific I/O modules (Analog, Digital, etc.) and the CP461/CP471 processor modules separately to complete your control station configuration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Dynamic Data Exchange (DDE) in Industrial Automation

Understanding Dynamic Data Exchange (DDE) in Industrial Automation

Dynamic Data Exchange (DDE) remains a vital legacy protocol for industrial communication. Originally for general computing, it now bridges the gap between factory floor data and enterprise reporting. This enduring method provides a foundational link for integrating real-time software layers in modern industrial automation.

Read more
Master FIFO and LIFO Sequences for Advanced PLC Logic

Master FIFO and LIFO Sequences for Advanced PLC Logic

In industrial automation, managing data flow is as critical as hardware control. This guide explores how FIFO and LIFO sequential logic can optimize your control systems. Master these essential tools to build more efficient sorting, inventory tracking, and data management workflows for any modern factory.

Read more
Power Cables vs. Signal Cables: Essential Guidelines for Industrial Automation

Power Cables vs. Signal Cables: Essential Guidelines for Industrial Automation

In industrial automation, distinguishing between power and signal cabling is vital. While power cables deliver energy to machinery, signal cables transmit critical data to control systems. This guide explores their technical differences and explains why proper isolation is the key to a reliable, interference-free factory automation network.

Read more