The ProSoft Technology AN-X2-AB-DHRIO gateway module provides seamless integration between modern Ethernet/IP networks and legacy Allen Bradley Remote I/O (RIO) and Data Highway Plus (DH+) systems. Designed for ControlLogix and CompactLogix environments, this communication module enables connectivity with PLCs, SLC 500 controllers, PanelView HMIs, drives, and Flex I/O adapters, ensuring reliable interoperability across mixed-generation automation systems.

Technical Specifications

  • Manufacturer: ProSoft Technology (Allen Bradley compatible)

  • Part Number: AN-X2-AB-DHRIO

  • Product Line: ControlLogix

  • Product Type: Communication Gateway Module

  • Weight: 0.69 lbs (≈ 0.31 kg)

  • Baud Rate Range: 57.6 to 230.4 kbaud

  • Supported Protocols: Ethernet/IP, Remote I/O (RIO), Data Highway Plus (DH+)

  • Rack Number Range: 0 to 76 octal

  • Ports:

    • 1 × 10/100 Mbps Ethernet/IP (RJ-45)

    • 1 × RIO/DH+ port

  • Power Supply: 24 VDC nominal

  • Voltage: 12 VDC

  • Current Consumption: 100 mA typical, 200 mA max

  • Power Dissipation: 2.4 W

  • Mounting Options: DIN rail or desktop installation

  • Supported Ethernet Devices: ControlLogix, CompactLogix

  • Supported RIO/DH+ Devices: PLC, SLC 500, PanelView HMIs, Drives, Flex I/O adapters

  • Maximum Supported Modules:

    • 32 RIO racks

    • 4 Ethernet/IP drives

    • 8 PanelView HMIs

  • Operating Temperature: 0–50 °C (32–122 °F)

  • Storage Temperature: -40–85 °C (-40–185 °F)

Application Scenarios

This gateway is ideal for facilities upgrading to Ethernet/IP while maintaining legacy RIO and DH+ devices. It allows seamless communication between modern controllers and older hardware, reducing downtime and simplifying migration strategies.

Comparison with Similar Modules

  • AN-X2-AB-DHRIO: Supports Ethernet/IP, RIO, and DH+ with broad device compatibility.

  • Other ProSoft gateways: May support only one protocol or limited device types, making them less versatile for mixed environments.

FAQ

Q: Can this gateway connect both Ethernet/IP and DH+ devices simultaneously?  A: Yes, it supports concurrent communication across Ethernet/IP and DH+ networks.

Q: How many PanelView HMIs can be connected?  A: Up to eight PanelView terminals can be supported on the same network.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more