Skip to content

What are you looking for?


You may also like

Allen-Bradley MVI56-MCM ControlLogix Modbus Communication ModuleAllen-Bradley MVI56-MCM ControlLogix Modbus Communication ModuleAllen-Bradley MVI56-MCM ControlLogix Modbus Communication Module
Allen-Bradley MVI56-MCM ControlLogix Modbus Communication Module
Allen-Bradley MVI56-MCM ControlLogix Modbus Communication Module
Allen-Bradley MVI56-MCM ControlLogix Modbus Communication Module

Allen-Bradley MVI56-MCM ControlLogix Modbus Communication Module


Only 10 left - Selling fast

PRODUCT SKU : MVI56-MCM

PRODUCT TYPE : Modbus Communication Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley MVI56-MCM is a Modbus communication module engineered for integration within the ControlLogix platform. It enables seamless data exchange between ControlLogix processors and Modbus-compatible devices, supporting both Modbus RTU and Modbus TCP/IP networks. Designed for reliability and high-performance control applications, the MVI56-MCM provides a robust interface for connecting PLCs to third-party field instruments and control systems.

Technical Specifications

  • Model / Part Number: MVI56-MCM

  • Brand: Allen-Bradley

  • Product Type: Modbus Communication Module

  • Product Line: ControlLogix

  • Weight: 1.69 lbs (0.77 kg)

  • Backplane Power Consumption: 800 mA @ 5 VDC

  • Supported Communication Protocols: Modbus RTU Master/Slave, Modbus TCP/IP

  • Supported Serial Standards: RS-232, RS-422, RS-485

  • Environmental Rating: Class I, Division 2, Groups A, B, C, and D (Hazardous Locations)

  • RAM Requirement: Minimum 128 MB, Recommended 256 MB

  • Operating Temperature: 32°F to 140°F (0°C to 60°C)

  • Required Disk Space (for configuration tools): Minimum 100 MB

  • Configuration Software: ProSoft Configuration Builder (PCB)

  • Mounting Type: ControlLogix chassis-mounted

  • Status Indicators: Module, Communication, and Network activity LEDs

  • Module Function: Acts as a communication bridge between Logix controllers and Modbus networks

Key Features

  • Dual Modbus ports for simultaneous master and slave operations

  • Compatible with standard ControlLogix backplanes

  • Simplified configuration through ProSoft software tools

  • Built for use in hazardous and industrial environments

  • Reliable real-time communication for Modbus-based control systems

Applications

  • Integration of legacy Modbus devices with modern ControlLogix PLCs

  • Industrial automation systems in oil and gas, power generation, and manufacturing

  • Supervisory control and data acquisition (SCADA) networks requiring Modbus communication

FAQs

Q1: Which communication modes does the MVI56-MCM support?
It supports both Modbus RTU and Modbus TCP/IP protocols, allowing flexible network integration.

Q2: Can it be installed in hazardous locations?
Yes. It is certified for Class I, Division 2, Groups A, B, C, and D environments.

Q3: What software is required for configuration?
The module is configured using ProSoft Configuration Builder (PCB), available from ProSoft Technology.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more