Skip to content

What are you looking for?


You may also like

Allen-Bradley Controllogix 1756-EN2TXT Extreme Environment EtherNet/IP ModuleAllen-Bradley Controllogix 1756-EN2TXT Extreme Environment EtherNet/IP ModuleAllen-Bradley Controllogix 1756-EN2TXT Extreme Environment EtherNet/IP Module
Allen-Bradley Controllogix 1756-EN2TXT Extreme Environment EtherNet/IP Module
Allen-Bradley Controllogix 1756-EN2TXT Extreme Environment EtherNet/IP Module
Allen-Bradley Controllogix 1756-EN2TXT Extreme Environment EtherNet/IP Module

Allen-Bradley Controllogix 1756-EN2TXT Extreme Environment EtherNet/IP Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-EN2TXT

PRODUCT TYPE : Communication Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 1756-EN2TXT (1756-EN2TXT) is a ruggedized EtherNet/IP bridge specifically engineered for the ControlLogix platform. As part of the "XT" (Extended Temperature) line, this module is built to withstand rigorous industrial conditions that exceed the limits of standard control hardware. It provides high-capacity data routing and serves as a critical interface for distributed I/O, peer-to-peer interlocking, and HMI/SCADA connectivity. The hardware features specialized conformal coating, providing an extra layer of protection against contaminants and corrosive vapors.

Core Technical Specifications

  • Network Throughput: 10/100 Mbps (Full or Half Duplex)

  • TCP/IP Capacity: 128 Simultaneous Connections

  • Logix Connections: 256 Maximum

  • Packet Performance: 25,000 pps (I/O and Explicit Messaging)

  • Backplane Current (5.1V DC): 1.0 Amps

  • Backplane Current (24V DC): 3.0 mA

  • Power Dissipation: 5.1 Watts

  • Thermal Dissipation: 17.4 BTU/hr

  • Isolation Voltage: 30V (continuous), Basic Insulation Type

  • USB Port: Version 1.1 (Type B) for local configuration and programming

  • Module Slot Width: 1 Slot (ControlLogix Chassis)

Extreme Environment Operating Parameters

  • Operating Temperature Range: -25°C to +70°C (-13°F to +158°F)

  • Storage Temperature Range: -40°C to +85°C (-40°F to +185°F)

  • Relative Humidity: 5% to 95% (Non-condensing)

  • Vibration Resistance: 2 g @ 10 to 500 Hz

  • Shock (Operating): 30 g

  • Shock (Non-operating): 50 g

  • Conformal Coating: Factory-applied (Standard on XT models)

Application Scenarios

The 1756-EN2TXT is the industry standard for decentralized control in harsh locations. Typical deployments include:

  • Mining & Metals: Reliable operation in high-vibration and dust-heavy processing plants.

  • Wastewater Treatment: Resistance to corrosive gases and high humidity via conformal coating.

  • Remote Power Generation: Stable communication in unconditioned cabinets subject to extreme seasonal temperature shifts.

Frequently Asked Questions

Q: Can I use the 1756-EN2TXT in a standard 1756-A7 chassis?A: Yes, the module is compatible with standard ControlLogix chassis, but to maintain the "Extreme Environment" rating for the entire system, it should be paired with other XT-rated components and chassis.

Q: Does the module support CIP Sync for motion applications?A: Yes, the 1756-EN2TXT supports CIP Sync (IEEE 1588 precision time protocol), making it suitable for synchronized distributed motion and high-precision sequence of events (SOE) applications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Functional Safety Terminology in Industrial Automation

Mastering Functional Safety Terminology in Industrial Automation

In modern process control and factory automation, managing operational risk is a top engineering priority. High-speed machinery, high-pressure vessels, and continuous processes present constant hazards to personnel and equipment. Modern plant operations rely heavily on functional safety strategies to mitigate these risks. This guide breaks down the essential functional safety terminology that every control systems engineer should master.

Read more
Understanding Dry Contacts in PLC Wiring: An Industrial Automation Guide

Understanding Dry Contacts in PLC Wiring: An Industrial Automation Guide

Mastering contact switching principles is essential for reliable control panels. Field devices and PLCs interface through dry or wet contacts. This technical guide examines the mechanics of dry contacts, explores their wiring architectures, and evaluates their key advantages in industrial automation.

Read more
Ultimate Commissioning Checklist for Industrial Automation Systems: An Engineering Guide

Ultimate Commissioning Checklist for Industrial Automation Systems: An Engineering Guide

Commissioning is the most decisive phase of an industrial automation project, transforming control hardware and software into an operational facility. Thorough testing prevents costly startup delays and builds customer confidence. This guide covers essential checklists, electrical standards, and best practices.

Read more