Product Details

Product Overview

The Allen Bradley 800T-N10 functions as a specialized safety accessory for the 800T series 30.5mm pilot devices. This padlock attachment provides a physical lockout mechanism for flush head push buttons, ensuring that only authorized personnel can actuate critical machine controls. By securing the button in its depressed or inactive state, the 800T-N10 directly supports facility Lockout/Tagout (LOTO) procedures and prevents accidental or malicious machinery startup.

Technical Specifications

Feature Details
Manufacturer Allen Bradley / Rockwell Automation
Part Number 800T-N10
Category Pilot Device Accessory
Compatibility 30.5 mm Flush Head Push Buttons
Attachment Type Padlockable Shroud/Hasp
Weight 0.05 lbs (0.02 kg)
Material Industrial-Grade Die-Cast Alloy/Steel
Condition 100% Brand New Original

Engineering Advantages

  • LOTO Compliance Integration: The 800T-N10 allows maintenance teams to apply standard padlocks to control interfaces. This mechanical barrier fulfills OSHA requirements for energy isolation at the operator station level.

  • Precision Fit for 30mm Operators: Designed specifically for the rugged 800T heavy-duty line, this attachment seats perfectly around the 30.5mm mounting hole. It maintains a low profile while providing enough clearance for standard padlock shackles.

  • Tamper Prevention: The robust construction resists forced removal. By shielding the flush head, the 800T-N10 eliminates the possibility of "accidental bumps" or unauthorized overrides during sensitive maintenance cycles.

  • Rapid Retrofitting: Engineers can install the 800T-N10 onto existing 800T push button assemblies without replacing the entire pilot device. The attachment slides over the operator head and secures tightly behind the mounting nut, requiring zero specialized tools.

  • Extreme Environment Durability: The metallic finish matches the heavy-duty specifications of the 800T series. It withstands oil, coolant, and metal shavings common in machining centers and automotive assembly lines.

FAQs

  • Is the 800T-N10 100% Brand New?

    Yes. We supply only Brand New, original Allen Bradley hardware. Each 800T-N10 arrives in its original factory packaging to ensure finish quality and fitment precision.

  • Does this attachment work with Extended Head push buttons?

    No. The 800T-N10 specifically fits Flush Head push buttons. Extended head or mushroom head operators require different lockout attachments (such as the 800T-N11) to accommodate the increased profile height.

  • Does the package include the padlock?

    No. The 800T-N10 is the mechanical attachment only. You must provide a standard industrial safety padlock to complete the lockout assembly.

  • Can I use this on 800H (4/4X rated) operators?

    While the 800T and 800H lines share similar mounting dimensions, we recommend using this specifically with 800T 30.5mm metal operators to ensure a proper environmental seal and mechanical alignment.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more