Skip to content

What are you looking for?


You may also like

Allen Bradley 1784-U2CN ControlNet USB Communication AdapterAllen Bradley 1784-U2CN ControlNet USB Communication AdapterAllen Bradley 1784-U2CN ControlNet USB Communication Adapter
Allen Bradley 1784-U2CN ControlNet USB Communication Adapter
Allen Bradley 1784-U2CN ControlNet USB Communication Adapter
Allen Bradley 1784-U2CN ControlNet USB Communication Adapter

Allen Bradley 1784-U2CN ControlNet USB Communication Adapter


Only 10 left - Selling fast

PRODUCT SKU : 1784-U2CN

PRODUCT TYPE : Communication Adapter

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1784-U2CN facilitates high-speed communication between a computer’s USB port and a ControlNet network. This industrial-grade adapter enables engineers to perform programming, configuration, and real-time diagnostics on ControlLogix, PLC-5, and SLC 500 systems via a standard USB 2.0 interface. It acts as a portable, high-performance gateway, replacing older, bulky PCMCIA or parallel port cards with a streamlined plug-and-play solution.

Technical Specifications

Parameter Value
Manufacturer Allen Bradley / Rockwell Automation
Part Number 1784-U2CN
Interface Type USB to ControlNet
Input Voltage 5.25 Volts DC (via USB Port)
Operating Current 225 mA
ControlNet Current 70 mA @ 24 Volts
Isolation Voltage 30 Volts
Protection Rating IP 30
Operating Temperature 0–55 °C (32–131 °F)
Condition 100% Brand New Original

Engineering Advantages

  • Eliminate Obsolete Hardware: The 1784-U2CN modernizes your toolkit by allowing modern laptops without legacy slots to interface directly with existing ControlNet infrastructures.

  • Bus-Powered Efficiency: The adapter draws its 5.25V DC power directly from the host USB port. This eliminates the need for external power bricks or localized AC outlets during field commissioning and site audits.

  • Ruggedized Portability: Weighing only 0.50 lbs, this compact unit withstands industrial environments. The IP30-rated enclosure protects internal circuitry from solid objects larger than 12mm, ensuring longevity during floor-level troubleshooting.

  • High-Voltage Isolation: With 30V isolation, the module shields your workstation or laptop from electrical noise and ground loops common in complex industrial networks, preventing hardware damage during live hot-plugging.

  • Broad Network Support: This cable supports multiple Allen Bradley platforms, making it a universal tool for facilities running a mix of legacy PLC-5 systems and modern ControlLogix architectures.

FAQs

  • Is this 1784-U2CN unit Brand New?

    Yes. We provide only 100% Brand New, original Allen Bradley equipment in factory-sealed packaging. This ensures maximum driver compatibility and hardware reliability.

  • Does the 1784-U2CN require a separate power supply?

    No. The device utilizes the power provided by your computer's USB port (5.25V DC, 225 mA), making it completely self-sufficient for mobile diagnostics.

  • Which operating systems support this adapter?

    The 1784-U2CN works with Windows-based environments that run RSLinx Classic. Always ensure you have the latest EDS files and drivers installed within your Rockwell software suite for seamless device recognition.

  • Can I use this for permanent installations?

    While primarily designed as a portable diagnostic and programming tool, its rugged IP30 enclosure allows it to remain connected for long-term monitoring tasks within a controlled panel environment.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more