Skip to content

What are you looking for?


You may also like

Allen-Bradley 1769-OF4 Compact I/O | Analog Output Module | CompactLogixAllen-Bradley 1769-OF4 Compact I/O | Analog Output Module | CompactLogixAllen-Bradley 1769-OF4 Compact I/O | Analog Output Module | CompactLogix
Allen-Bradley 1769-OF4 Compact I/O | Analog Output Module | CompactLogix
Allen-Bradley 1769-OF4 Compact I/O | Analog Output Module | CompactLogix
Allen-Bradley 1769-OF4 Compact I/O | Analog Output Module | CompactLogix

Allen-Bradley 1769-OF4 Compact I/O | Analog Output Module | CompactLogix


Only 10 left - Selling fast

PRODUCT SKU : 1769-OF4

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 1769-OF4 Compact I/O Analog Output Module provides four single-ended channels for precise voltage and current signal generation. Designed for CompactLogix and MicroLogix 1500 controllers, it ensures reliable performance in demanding automation environments.

Technical Specifications

  • Manufacturer Allen-Bradley

  • Product Line CompactLogix / Compact I/O

  • Part Number 1769-OF4

  • Module Type Analog Output

  • Outputs Four single-ended channels

  • Compatible Controllers CompactLogix, MicroLogix 1500

  • Analog Ranges Voltage: ±10V, 0–10V, 0–5V, 1–5V; Current: 0–20 mA, 4–20 mA

  • Full Scale Ranges Voltage: ±10.5V, -0.5–10.5V, -0.5–5.25V, 0.5–5.25V; Current: 0–21 mA, 3.2–21 mA

  • Conversion Rate 2.5 ms

  • Data Format 15-bit plus sign, unipolar/bipolar

  • Series A and B

  • Power Supply Distance Rating 8 modules

  • Current Draw @ 5.1V 120 mA

  • Current Draw @ 24V 170 mA

  • Heat Dissipation 2.86 W

  • Wire Type Copper

  • Solid Wire Size 22–14 AWG

  • Stranded Wire Size 22–16 AWG

  • Replacement Terminal Block 1769-RTBN18

  • Replacement Door 1769-RD

  • Calibration Not required (hardware design ensures accuracy)

  • Non-Linearity ±0.05% full scale

  • Slot Width 1 module

Application Scenarios

  • Integration with CompactLogix systems for analog signal control

  • Process automation requiring precise voltage/current outputs

  • Industrial setups with MicroLogix 1500 controllers

  • Signal interfacing for sensors, actuators, and instrumentation

FAQ

Q: Is calibration necessary for the 1769-OF4?  A: No, calibration is not required. The hardware design guarantees accuracy.

Q: Which controllers are supported?  A: The module works with CompactLogix and MicroLogix 1500 controllers.

Q: Can it output both current and voltage signals?  A: Yes, it supports multiple ranges for both current and voltage outputs.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Modern control systems rely heavily on seamless interprocess communication to exchange operational data between software programs. Microsoft first introduced the Dynamic Data Exchange (DDE) protocol in 1987 to enable real-time data sharing. In factory automation, DDE served as an early bridge between control software and Windows desktop applications. Therefore, understanding DDE mechanics provides crucial insights into how legacy industrial networks established software-level connectivity.

Read more
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more