Skip to content

What are you looking for?


You may also like

Allen-Bradley 1762-OW16 MicroLogix 1200 Relay Output ModuleAllen-Bradley 1762-OW16 MicroLogix 1200 Relay Output ModuleAllen-Bradley 1762-OW16 MicroLogix 1200 Relay Output Module
Allen-Bradley 1762-OW16 MicroLogix 1200 Relay Output Module
Allen-Bradley 1762-OW16 MicroLogix 1200 Relay Output Module
Allen-Bradley 1762-OW16 MicroLogix 1200 Relay Output Module

Allen-Bradley 1762-OW16 MicroLogix 1200 Relay Output Module


Only 10 left - Selling fast

PRODUCT SKU : 1762-OW16

PRODUCT TYPE : Relay Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1762-OW16 is a high-performance relay output module for MicroLogix 1200 series controllers. It provides sixteen isolated AC/DC relay outputs grouped into two independent banks, enabling flexible control of industrial loads. Designed for DIN rail mounting, this module ensures reliable switching performance with minimal signal delay.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Model Number: 1762-OW16

  • Product Type: Relay Output Module

  • Compatible Controllers: MicroLogix 1100 / 1200 / 1400

  • Mounting Type: DIN Rail

  • Isolated Groups: 2

  • Total Outputs: 16 AC/DC relay channels

  • Relay Contact Voltage Ratings: 24–125 VDC; 120–240 VAC

  • Operating Voltage Range: 5–265 V AC; 5–125 V DC

  • Channels per Group: 8

  • Signal Delay: 10 ms

  • Maximum Current per Point: 2.5 A

  • Heat Dissipation: 6.1 W

  • Weight: 0.69 lbs (0.31 kg)

Key Features

  • Two isolated relay groups for independent load control

  • DIN rail mounting for easy integration into MicroLogix systems

  • Supports AC and DC loads across a wide voltage range

  • Fast response time of 10 ms for precise switching

  • Robust design with 2.5 A per channel capacity

Application Scenarios

  • Switching AC or DC actuators in MicroLogix-controlled automation systems

  • Controlling small motors, solenoids, or indicator circuits

  • Ideal for applications requiring multiple independent relay outputs

  • Suitable for factory automation, process control, or general industrial use

FAQ

Q1: How many isolated relay groups does the 1762-OW16 provide?
A1: The module has two independent isolated groups with 8 channels each.

Q2: What is the maximum current rating per relay output?
A2: Each relay channel supports up to 2.5 A.

Q3: Which controllers is this module compatible with?
A3: It works with MicroLogix 1100, 1200, and 1400 series controllers.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more