Product Details

Product Overview

The Allen Bradley 1756-L72S functions as a high-performance GuardLogix 5570 series controller, providing integrated safety and discrete control in a single platform. This processor handles SIL 3 and PLe (Performance Level e) safety applications when paired with its mandatory safety partner. It manages high-speed motion, complex safety logic, and standard process control simultaneously, eliminating the need for separate safety relays or independent systems. We supply this unit as 100% Brand New original factory stock, ensuring the hardware integrity required for critical life-safety automation.

Technical Specifications

Feature Specification Details
User Memory 4 MB Standard
Safety Memory 2 MB Integrated
Non-Volatile Memory 1 GB (Included Secure Digital Card)
Max Digital I/O 128,000 Points
Max Analog I/O 4,000 Points
Tasks 31 Standard; 1 Safety
Programs per Task 100 Programs
Communication 1 USB Port (Programming/Diagnostics)
Energy Storage 1756-ESMCAP (Removes need for batteries)
Current Draw 800 mA @ 5.1V DC; 5 mA @ 1.2V DC
Power Dissipation 2.5 Watts
Thermal Dissipation 8.5 BTU/hr

Engineering Advantages

  • Integrated Safety Architecture: The 1756-L72S executes both standard and safety instructions within the same chassis. This architecture simplifies software development in Studio 5000, as engineers use a common tag database for both safety and standard logic, reducing programming errors and commissioning time.

  • Battery-Free Operation: The module utilizes the 1756-ESMCAP energy storage module. This capacitor-based technology provides sufficient power to save the project to non-volatile memory during a power loss event. This eliminates the maintenance burden and environmental hazards associated with traditional lithium batteries.

  • High-Resolution Diagnostic Throughput: The integrated USB 2.0 port supports rapid firmware flashing and high-speed online edits. Unlike older serial-based processors, the 1756-L72S allows for near-instantaneous uploads and downloads, which is critical during emergency downtime recovery.

  • Massive I/O Scalability: Supporting up to 128,000 digital I/O points, this controller manages large-scale manufacturing cells. It maintains consistent scan times even under heavy logic loads, ensuring that safety reaction times remain within the required performance parameters for SIL 3 compliance.

FAQs

  • Does the 1756-L72S require a safety partner to function?

    Yes. To achieve SIL 3/PLe safety ratings, you must pair the 1756-L72S with the 1756-L7SP safety partner controller. The partner module provides the redundancy required to cross-check safety logic execution and ensure a fail-safe state in the event of a processor fault.

  • What is the advantage of the 1GB non-volatile memory card?

    The ships-with 1GB SD card stores the user program and tag data permanently. If a processor failure occurs, maintenance personnel can simply move the SD card to a new 1756-L72S unit to restore the system without needing a programming laptop or the original source code files.

  • Can I use this controller in an existing 1756 ControlLogix chassis?

    The 1756-L72S is compatible with all standard 1756-A4, A7, A10, A13, and A17 chassis. However, ensure that your power supply (e.g., 1756-PA72 or PB72) provides enough current for the processor and its safety partner, as they draw significantly more power than standard L7 series controllers.

  • Is this a refurbished unit?

    No. We guarantee this 1756-L72S is 100% Brand New original Allen Bradley equipment. It arrives in the original factory box with the factory seal intact, including the pre-installed energy storage module and SD card.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more