Skip to content

What are you looking for?


You may also like

Allen-Bradley 1756-IF8I ControlLogix Isolated Analog Input ModuleAllen-Bradley 1756-IF8I ControlLogix Isolated Analog Input ModuleAllen-Bradley 1756-IF8I ControlLogix Isolated Analog Input Module
Allen-Bradley 1756-IF8I ControlLogix Isolated Analog Input Module
Allen-Bradley 1756-IF8I ControlLogix Isolated Analog Input Module
Allen-Bradley 1756-IF8I ControlLogix Isolated Analog Input Module

Allen-Bradley 1756-IF8I ControlLogix Isolated Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-IF8I

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1756-IF8I is an isolated analog input module designed for high-accuracy signal measurement in ControlLogix systems. With eight individually isolated input channels, it supports both voltage and current inputs, providing exceptional precision and noise immunity for process and automation applications.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: ControlLogix

  • Part Number: 1756-IF8I

  • Module Type: Isolated Analog Input Module

  • Number of Channels: 8 isolated analog inputs

  • Input Signal Ranges:

    • ±10V

    • 0–10V

    • 0–5V

    • 0–21 mA (current)

  • Resolution: 24-bit (1.49 µV/count for voltage, 2.99 nA/count for current)

  • Input Current Range: 0–20 mA

  • Channel Isolation: 250V continuous (reinforced or basic insulation)

  • Power Consumption:

    • 15.7 BTU/hr (voltage mode)

    • 17.4 BTU/hr (non-sourcing current mode)

    • 24.9 BTU/hr (sourcing current mode)

  • Update Time: 1 ms for floating-point values

  • Calibration: Factory calibrated, no field calibration required

Key Features

  • Multi-Mode Input Support: Handles voltage, current, and 2-wire transmitter input configurations.

  • High Accuracy and Resolution: 24-bit resolution provides precise signal measurement for demanding applications.

  • Individual Channel Isolation: Each input channel is electrically isolated to reduce noise and ensure safety.

  • Real-Time Data Sampling: Synchronized input sampling supports accurate, real-time control across the system.

  • No Field Calibration: Simplifies installation and maintenance by eliminating manual adjustments.

  • Status Indicators: Per-channel LEDs provide diagnostic and fault information for simplified troubleshooting.

Application Scenarios

  • Process Automation: Measurement of temperature, pressure, and flow signals.

  • Industrial Monitoring: Data acquisition from analog sensors and transmitters.

  • Machine Control Systems: Integration into ControlLogix racks for precision signal monitoring.

  • Energy Management: Accurate analog data input for metering and efficiency control.

FAQs

  • Q: How many input channels does the 1756-IF8I provide?
    A: The module includes eight isolated analog input channels.

  • Q: What input ranges are supported?
    A: Voltage ranges ±10V, 0–10V, 0–5V, and current range 0–21 mA.

  • Q: Does it require manual calibration?
    A: No, it is factory calibrated and requires no field calibration.

  • Q: What level of isolation does it offer?
    A: Provides up to 250V continuous isolation between channels.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more