Skip to content

What are you looking for?


You may also like

Allen-Bradley 1756-IF16H ControlLogix 16-Point Analog Input HART ModuleAllen-Bradley 1756-IF16H ControlLogix 16-Point Analog Input HART ModuleAllen-Bradley 1756-IF16H ControlLogix 16-Point Analog Input HART Module
Allen-Bradley 1756-IF16H ControlLogix 16-Point Analog Input HART Module
Allen-Bradley 1756-IF16H ControlLogix 16-Point Analog Input HART Module
Allen-Bradley 1756-IF16H ControlLogix 16-Point Analog Input HART Module

Allen-Bradley 1756-IF16H ControlLogix 16-Point Analog Input HART Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-IF16H

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1756-IF16H is a high-performance ControlLogix analog input module supporting HART protocol on each channel. It provides 16 differential analog inputs with dedicated HART modems, suitable for precise process control and integration with PanelView Plus operator terminals.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: ControlLogix

  • Model / Part Number: 1756-IF16H

  • Product Type: Analog Input Module with HART Protocol

  • Module Type: 16-Point Differential Analog Input with Dedicated HART Modems

  • Analog Signal Range: 0–20 mA, 4–20 mA

  • Resolution: 16–21 Bits

  • Data Format: Integer mode (left-justified, 2’s complement), IEEE 32-bit floating point

  • Conversion Method: Successive approximation

  • Module Scan Time: 11–328 ms (filter dependent)

  • HART Scan Time: Approx. 1 s when all channels enabled

  • Inputs: 16 differential

  • Backplane Current: 5.1V DC – 200 mA; 24V DC – 125 mA

  • Total Backplane Power: 4.02 W

  • Input Overvoltage Protection: 8 V DC

  • Isolation Voltage: 50 V continuous

  • Removable Terminal Block: 1756-TBCH; 1756-TBS6H

  • Enclosure Type: Open

Key Features

  • Dedicated HART modem per channel for precise digital communication

  • Supports high-resolution analog input conversion

  • Flexible scan rates with filter options for signal stabilization

  • Compatible with PanelView Plus operator terminals and ControlLogix controllers

  • Removable terminal blocks simplify wiring and maintenance

Application Scenarios

  • Industrial process monitoring requiring HART-enabled devices

  • Multi-channel analog signal acquisition in ControlLogix systems

  • Integration with PanelView Plus and PanelView Plus CE operator terminals

  • Precise measurement and data acquisition in process automation

FAQs

Q: Can all channels run HART simultaneously?
A: Yes, all 16 channels can operate HART protocol simultaneously, with an estimated 1-second scan per module.

Q: What type of analog inputs are supported?
A: 16 differential channels supporting 0–20 mA and 4–20 mA signals.

Q: Is there overvoltage protection?
A: Yes, each input channel supports up to 8 V DC overvoltage protection.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more