Overview
The 1747-ASB by Allen-Bradley is a versatile Universal Remote I/O Adapter designed for SLC 500 systems. It enables remote connectivity to distributed I/O devices while maintaining high communication reliability.

Technical Specifications

  • Brand & Model: Allen-Bradley 1747-ASB

  • Product Type: Universal Remote I/O Adapter Module

  • Product Line: SLC 500

  • Weight: 0.50 lbs (0.23 kg)

  • Module Type: I/O Adapter

  • Communication Port: Universal Remote I/O

  • Communication Rate: 57.6, 115, or 230 kbps

  • Backplane Current (5 V DC): 375 mA

  • Cable Type: Belden 9463

  • Slot Width: 1 slot

  • Maximum Slots Supported: 30 slots

  • Node Capacity: 16 standard nodes; 32 extended nodes

  • Connector Type: 6-pin Phoenix connector

  • Operating Temperature Range: 0–60°C

Applications
The 1747-ASB is ideal for connecting remote SLC 500 I/O racks to a main controller, enabling scalable control architectures. It supports both standard and extended node configurations for larger automation systems.

FAQ

Q: What cable type is recommended for the 1747-ASB?
A: Use Belden 9463 for optimal communication performance.

Q: How many nodes can this module support?
A: Up to 16 standard nodes or 32 nodes with the extended configuration.

Q: Can it be mounted in a standard SLC 500 rack?
A: Yes, it occupies one slot and is fully compatible with SLC 500 backplanes.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more