Overview

The Allen-Bradley 1734-ADN is a high-performance POINT I/O DeviceNet adapter designed to connect distributed I/O modules to DeviceNet networks. With support for up to 63 powered modules and a maximum of 504 I/O points, the 1734-ADN ensures flexible and scalable control for industrial automation systems. Compact dimensions and low weight make it suitable for installation in dense control cabinets while providing reliable communication across the network.

Specifications

I/O Capacity

  • Maximum Powered Modules: 63

  • Integrated I/O Channels: 0

  • Maximum I/O Points: 504

  • DeviceNet Nodes (with max I/O): 1

  • Node Address: 1

  • I/O Module Capacity: 63

Electrical Parameters

  • DeviceNet Current: 30 mA

  • POINTBus Current: 1000 mA @ 5 V DC ±5% (4.75–5.25 V)

Physical Dimensions

  • Dimensions (LxWxH): 12.2 cm × 5.49 cm × 13.34 cm

  • Weight: 0.3 kg

Features

  • Scalable I/O Support: Connects up to 63 POINT I/O modules for flexible system expansion

  • High I/O Density: Handles up to 504 I/O points for comprehensive control applications

  • Compact Design: Lightweight and space-saving for dense cabinet installations

  • DeviceNet Integration: Reliable communication with DeviceNet networks, supporting one node per maximum I/O configuration

  • Efficient Power Management: Low DeviceNet and POINTBus current consumption for energy-efficient operation

Applications

The 1734-ADN adapter is ideal for distributed I/O configurations in process control, factory automation, and other industrial systems requiring reliable DeviceNet connectivity. It enables rapid expansion of POINT I/O networks while maintaining precise control over large numbers of I/O points.

FAQ

Q: How many POINT I/O modules can the 1734-ADN support?
A: The module supports up to 63 powered POINT I/O modules.

Q: What is the maximum number of I/O points?
A: The 1734-ADN can handle a total of 504 I/O points.

Q: What is the required Node Address?
A: When configured with maximum I/O, the node address is 1.

Q: Can it operate in compact control cabinets?
A: Yes, with dimensions of 12.2 × 5.49 × 13.34 cm and weight of 0.3 kg, it is suitable for tight installations.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more