Skip to content

What are you looking for?


You may also like

Allen-Bradley 1715-TASOB8DE 8-Point Termination AssemblyAllen-Bradley 1715-TASOB8DE 8-Point Termination AssemblyAllen-Bradley 1715-TASOB8DE 8-Point Termination Assembly
Allen-Bradley 1715-TASOB8DE 8-Point Termination Assembly
Allen-Bradley 1715-TASOB8DE 8-Point Termination Assembly
Allen-Bradley 1715-TASOB8DE 8-Point Termination Assembly

Allen-Bradley 1715-TASOB8DE 8-Point Termination Assembly


Only 10 left - Selling fast

PRODUCT SKU : 1715-TADOBA8DE

PRODUCT TYPE : Termination Assembly

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 1715-TASOB8DE termination assembly provides a reliable interface for connecting field wiring to the 1715 redundant I/O system. Designed with precision and durability, this module ensures secure signal transmission and simplifies installation in distributed control environments.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: 1715 Redundant I/O System

  • Part Number: 1715-TASOB8DE

  • Product Type: 8-Point Termination Assembly

  • Connection Capacity: 8 input/output points

  • Form Factor: Compact design for efficient panel space usage

  • Wiring Interface: Screw-type terminals for secure connections

  • Environmental Ratings:

    • Operating Temperature: 0 °C to 60 °C

    • Humidity: Up to 95% non-condensing

    • Altitude: -1000 to 5000 meters

  • Reliability Features: Designed for redundant I/O applications, minimizing downtime risks

Application Scenarios

  • Used in redundant control systems requiring high availability.

  • Suitable for process industries such as oil & gas, chemical, and power generation.

  • Provides simplified wiring and termination for distributed I/O modules.

FAQ

Q: What is the purpose of the 1715 termination assembly?  A: It provides the physical connection point for field wiring to the redundant I/O modules.

Q: How many signals can be connected?  A: The 1715-TASOB8DE supports up to 8 I/O points.

Q: Is this assembly compatible with all 1715 modules?  A: Yes, it is designed specifically for use with the 1715 redundant I/O system.

Comparable Models

  • 1715-TASOB16DE: 16-point termination assembly for larger signal capacity.

  • 1715-TASOB4DE: 4-point version for smaller-scale applications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Batch vs Continuous Processing in Industrial Automation: Architectural Strategies for Control Engineers

Batch vs Continuous Processing in Industrial Automation: Architectural Strategies for Control Engineers

Selecting the proper control architecture remains a pivotal decision when designing industrial automation systems. Automation engineers must evaluate whether a batch or continuous process model best fits their production requirements. This fundamental choice influences PLC and DCS programming, hardware redundancy, sensor selection, and overall factory automation layouts.

Read more
Demystifying Signal Isolators: Operating Principles, Architectural Types, and Industrial Applications

Demystifying Signal Isolators: Operating Principles, Architectural Types, and Industrial Applications

Industrial automation systems rely on pristine analog signal transmission across complex control loops. Instrument technicians and system integrators frequently deploy signal isolators to maintain signal integrity between field sensors and control platforms. Eliminating electrical noise, ground loops, and high-voltage transients protects delicate PLC, DCS, and SCADA input channels from permanent damage.

Read more
Demystifying Industrial Control Systems: Comparing PLC, DCS, RTU, SCADA, and PAC

Demystifying Industrial Control Systems: Comparing PLC, DCS, RTU, SCADA, and PAC

Modern factory automation relies on distinct control architectures to manage complex process environments efficiently. Control engineers often evaluate PLC, DCS, RTU, SCADA, and PAC platforms when designing industrial infrastructure. Understanding the functional boundaries of each technology ensures optimal system performance, high availability, and long-term cost efficiency.

Read more