PRODUCT SKU : 51308058-100

PRODUCT TYPE : Interface Cables

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for signal transmission in TDC 3000 Distributed Control System (DCS) operator stations, the Honeywell 51308058-100 (51308058-100 Keyboard Interface Cable Assembly) provides direct physical and electrical execution of keyboard-to-console data communication.

Hardware Specifications

Parameter Specification
Model 51308058-100
Brand Honeywell
Weight 0.5 kg
Dimensions 2-3 m length
Operating Temp 0 to 55 deg C
Power Consumption Not Applicable
Connector Type Honeywell proprietary console
Cable Type Keyboard interface

DCS Process Control and Connectivity

The 51308058-100 utilizes industrial-grade electromagnetic interference (EMI) and radio frequency interference (RFI) shielding to maintain signal integrity during operator data entry. In DCS environments, high-frequency noise can introduce latency or character corruption in console communication loops. This assembly integrates channel-to-channel isolation principles for internal data lines, ensuring that the proprietary connector interface maintains a stable connection between the operator keyboard and the console electronics. The design minimizes signal degradation over the 2-3 m cable span, preventing common-mode noise propagation that could trigger diagnostic faults within the operator station interface.

Frequently Asked Questions

Q: Is this cable assembly compatible with non-Honeywell keyboard interfaces?

A: No. The 51308058-100 features a Honeywell proprietary console connector interface. It is strictly designed for use with TDC 3000 operator stations and cannot be adapted for standard USB or PS/2 interfaces without custom hardware conversion.

Q: How should the cable be routed to maintain EMI/RFI shielding effectiveness?

A: The cable should be routed through dedicated conduit or cable trays, physically separated from high-voltage power lines and large electromagnetic sources (such as variable frequency drives or heavy motors) to avoid inductive interference.

Field Installation Guidelines

  1. Ensure the operator station power is stable and the console is in a safe state before connecting or disconnecting the interface cable.
  2. Align the proprietary connector housing with the console receptacle, ensuring proper key orientation before applying pressure.
  3. Fully seat the connector until the locking mechanism engages, preventing intermittent connections caused by operator movement.
  4. Verify cable strain relief by ensuring that no excessive tension is placed on the connectors, which could lead to pin fatigue or mechanical failure.
  5. Perform a test input sequence at the operator console to confirm that all keystroke signals are correctly registered by the TDC 3000 system.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more