Skip to content

What are you looking for?


You may also like

5069-L330ERS2 | Allen-Bradley | Compact GuardLogix 5380 SIL 2 Safety Controller5069-L330ERS2 | Allen-Bradley | Compact GuardLogix 5380 SIL 2 Safety Controller5069-L330ERS2 | Allen-Bradley | Compact GuardLogix 5380 SIL 2 Safety Controller
5069-L330ERS2 | Allen-Bradley | Compact GuardLogix 5380 SIL 2 Safety Controller
5069-L330ERS2 | Allen-Bradley | Compact GuardLogix 5380 SIL 2 Safety Controller
5069-L330ERS2 | Allen-Bradley | Compact GuardLogix 5380 SIL 2 Safety Controller

5069-L330ERS2 | Allen-Bradley | Compact GuardLogix 5380 SIL 2 Safety Controller


Only 10 left - Selling fast

PRODUCT SKU : 5069-L330ERS2

PRODUCT TYPE : Safety Controller

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 5069-L330ERS2 functions as a high-performance Compact GuardLogix 5380 safety controller, providing integrated safety and standard control within a single chassis. This module executes complex safety logic up to SIL 2 / PLd standards while simultaneously managing standard automation tasks. It utilizes a dual-core processor to optimize high-speed communication and motion throughput. We supply this controller as 100% Brand New and factory-original, ensuring your safety systems operate with the highest integrity and the latest hardware revisions.

Technical Specifications

This controller delivers high-bandwidth performance and localized I/O expansion for modern smart manufacturing.

Feature Specification
User Memory 3 MB Standard
Safety Memory 1.5 MB
SIL Rating SIL 2 / PLd
Ethernet Speed 10 Mbps / 100 Mbps / 1 Gbps (Gigabit)
Ethernet Nodes Supports up to 60 Nodes
Local I/O Capacity Supports up to 31 Modules
Network Topologies Device Level Ring (DLR), Star, Linear
Non-Volatile Memory 2GB (via included 1784-SD2 card)
Programming Ladder, Structured Text, Function Block, SFC

Engineering Advantages

  • Dual-Port Gigabit Ethernet: The integrated dual ports support high-speed 1Gbps communication. This bandwidth ensures rapid data exchange between nodes and prevents network bottlenecks in data-intensive applications like integrated motion and complex safety sensing.

  • Integrated Safety & Standard Control: The 5069-L330ERS2 eliminates the need for separate safety and standard PLCs. This convergence reduces panel space requirements, simplifies inventory management, and streamlines the programming environment via Studio 5000 Logix Designer.

  • Advanced DLR Resilience: The controller supports Device Level Ring (DLR) topology. This allows the system to maintain communication even if a physical break occurs in the network ring, preventing costly downtime and ensuring continuous safety monitoring.

  • Enhanced Local I/O Expansion: The 5069 platform allows for 31 local I/O modules. This high density provides massive localized control capability without requiring additional remote adapter hardware, effectively reducing system latency and installation costs.

FAQs

  • Does the 5069-L330ERS2 ship with a memory card?

    Yes. Every Brand New unit includes a 1784-SD2 2GB Secure Digital card. This card provides non-volatile storage for your user program and tag data, allowing for rapid controller replacement without a PC.

  • What is the maximum number of safety tasks this controller can handle?

    The module supports exactly 1 dedicated Safety Task alongside 31 Standard tasks. This dedicated task ensures that safety logic executes with consistent priority and deterministic timing.

  • Can I use this controller for high-speed motion control?

    While the 5069-L330ERS2 supports integrated motion on EtherNet/IP, it is specifically configured for "No Maximum" axes in this variant. It excels at safety monitoring and coordinated control; for high-axis count synchronized motion, verify your specific axis requirements against the L330ERM or higher models.

  • How do I ensure SIL 2 compliance during installation?

    You must follow the Allen-Bradley Safety Reference Manual instructions. Use only approved 5069-series safety I/O modules and ensure the safety signature matches your validated code to maintain the SIL 2 certification for the entire loop.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the 5 Levels of Industrial Automation Architecture

Demystifying the 5 Levels of Industrial Automation Architecture

Modern manufacturing relies on structured communication hierarchy to bridge physical shop-floor hardware with enterprise management software. This framework, commonly known as the Automation Pyramid, establishes how data flows between field devices, logic controllers, and corporate IT networks. Understanding these five distinct levels helps engineers and plant managers optimize system operations, reduce downtime, and implement seamless factory automation solutions.

Read more
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more