PRODUCT SKU : 330104-08-15-10-02-CN

PRODUCT TYPE : Proximity Sensors

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Bently Nevada 330104-08-15-10-02-CN is a 3300 XL 8 mm proximity probe configured with an 80 mm unthreaded length, 150 mm overall case length, and 1.0 m (3.3 ft) total length. It uses a standard cable with a miniature coaxial ClickLoc connector and carries ATEX/IECEx and Chinese NEPSI hazardous area marking.

Configuration and Ordering Options

This part number defines a 330104 3300 XL 8 mm probe with an 80 mm unthreaded section and a 150 mm overall case length, supporting installations that require an extended probe body and a defined unthreaded standoff length. The 1.0 m (3.3 ft) total length uses a standard cable and terminates in a miniature coaxial ClickLoc connector.

Agency approval is set to CN, specifying ATEX/IECEx and Chinese NEPSI hazardous area marking. Confirm exact hazardous area ratings, installation conditions, and site permit requirements before deployment.

Hardware Specifications

Parameter Specification
Model 330104-08-15-10-02-CN
Brand Bently Nevada
Probe Type 3300 XL 8 mm probe (model 330104)
Unthreaded Length 80 mm (option 08)
Overall Case Length 150 mm (option 15)
Total Length 1.0 m (3.3 ft) (option 10)
Cable and Connector Standard cable, miniature coaxial ClickLoc connector (option 02)
Agency Approval ATEX/IECEx and Chinese NEPSI hazardous area marking (option CN)

Frequently Asked Questions

Q: What case dimensions and cable length are specified for 330104-08-15-10-02-CN?

A: It specifies an 80 mm unthreaded length, a 150 mm overall case length, and a 1.0 m (3.3 ft) total length with a standard cable and miniature coaxial ClickLoc connector.

Q: Which hazardous area markings apply to this configuration?

A: This configuration includes ATEX/IECEx and Chinese NEPSI hazardous area marking under option CN. Verify exact hazardous location ratings and site permit requirements before installation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Guide to Grounding Electronic Equipment in Industrial Automation

Essential Guide to Grounding Electronic Equipment in Industrial Automation

Industrial automation systems require robust grounding for personal safety and fault clearance. Safety grounding minimizes touch potential across exposed metallic enclosures. It ensures rapid clearance of fuses during electrical faults. However, electronic equipment introduces unique performance requirements. Solid-state devices operate at high speeds. Therefore, they exhibit extreme sensitivity to minor voltage transients. Facility engineers must balance electrical safety with operational signal integrity.

Read more
Engineering Guide to Selecting Electrical Earthing and Grounding Components in Industrial Automation

Engineering Guide to Selecting Electrical Earthing and Grounding Components in Industrial Automation

The overall reliability of any industrial automation network relies heavily on its grounding components. Control systems, PLCs, and distributed control systems (DCS) require rigorous earthing to mitigate electrical noise and faults. Engineers must select each component with extreme care. Furthermore, proper interconnection methods dictate whether a facility operates safely or suffers from chronic signal disruption.

Read more
Mastering Electrical Ground Loop Mitigation in Industrial Automation and Control Systems

Mastering Electrical Ground Loop Mitigation in Industrial Automation and Control Systems

Ground loops represent one of the most persistent challenges in industrial automation, PLC networks, and distributed control systems (DCS). According to IEEE Std. 100-1991, a ground loop forms when two or more points nominally at ground potential connect through a conducting path, creating potential differences. In sensitive analog and digital signal circuits, this unwanted conductive path allows noise currents to superimpose directly onto process signals.

Read more