Product Description

The 2711-K9C8 is a robust operator interface terminal from the Allen-Bradley PanelView 900 Standard series, engineered for high-performance monitoring and control in industrial environments. This unit features a 9-inch Active Matrix TFT color display with a 640 x 400 resolution, providing sharp visual feedback for complex automation processes. Unlike touch-only models, the 2711-K9C8 (Catalog Number: 2711-K9C8) is equipped with a heavy-duty stainless-steel domed keypad assembly, including 16 programmable function keys (F1 through F16) for tactile, precise operator input.

This terminal is designed for seamless integration into legacy Data Highway Plus (DH+) networks, featuring a dedicated DH+ communication port along with an auxiliary RS-232 port for serial printing requirements. Built to withstand demanding factory conditions, the housing is rated for NEMA 4X and IP65 protection, ensuring resistance against dust and liquid ingress when panel-mounted. The internal architecture includes 1008 KB of nonvolatile flash memory to support rich graphical objects, bitmaps, and extensive alarm text.

Technical Specifications

  • Manufacturer: Allen-Bradley / Rockwell Automation

  • Model Number: 2711-K9C8

  • Operator Input: Tactile Keypad (16 Function Keys)

  • Display Technology: 9-inch Color Active Matrix TFT

  • Backlight Component: CCFL (Replacement part 2711-NL2)

  • Effective Display Area: 210 x 131 mm (8.27 x 5.17 in.)

  • Primary Communication: Data Highway Plus (DH+)

  • Peripheral Interface: RS-232 Printer Port

  • Memory Capacity: 1008 KB Nonvolatile (App Objects); 310 KB Runtime

  • Power Requirements: 85 to 264V AC (Universal Input)

  • Frequency Range: 47 to 63 Hz

  • Environmental Ratings: NEMA Type 12/13, 4X; IP54, IP65

  • Diagnostic Indicators: COMM (Green LED), FAULT (Red LED)

  • Shipping Weight: 3.20 kg (7.06 lbs)

Selection and Maintenance

The 2711-K9C8 is primarily used to replace or maintain legacy HMI systems connected to PLC-5 or SLC 500 controllers via DH+. When performing maintenance, ensure the 2711-NC14 communication cable is utilized for stable signal integrity. If the screen becomes dim, the 2711-NL2 backlight lamp can be field-replaced to extend the unit's operational life.

Engineering FAQ

What software is required to modify the application on a 2711-K9C8?The PanelView 900 Standard series is programmed using PanelBuilder32 software. While modern FactoryTalk View Studio can import these files, native edits require the legacy PanelBuilder environment.

How does this model handle power fluctuations?The 2711-K9C8 features a wide-range universal AC power supply. It can handle input voltages from 85V up to 264V AC, making it resilient against the voltage sags common in heavy industrial start-up cycles.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Modern industrial automation heavily relies on Programmable Logic Controllers (PLCs) to drive factory floor efficiency. Over my 15 years as an industrial automation expert working with DCS, TSI, and control systems, I have seen PLCs evolve into the central nervous system of modern manufacturing. Selecting the right controller requires a deep understanding of PLC types based on physical size, hardware architecture, and power supply configurations.

Read more
Comprehensive Guide to PLC Types in Modern Industrial Automation

Comprehensive Guide to PLC Types in Modern Industrial Automation

Modern industrial automation relies on programmable logic controllers to govern critical factory operations. System integrators classify PLCs based on scale, hardware architecture, and power supply design. Understanding these core categories enables automation engineers to select the right control system architecture. Consequently, proper hardware selection optimizes performance while minimizing long-term operational costs.

Read more
Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Modern control systems rely heavily on seamless interprocess communication to exchange operational data between software programs. Microsoft first introduced the Dynamic Data Exchange (DDE) protocol in 1987 to enable real-time data sharing. In factory automation, DDE served as an early bridge between control software and Windows desktop applications. Therefore, understanding DDE mechanics provides crucial insights into how legacy industrial networks established software-level connectivity.

Read more